THE

HEXAGON HEAD.
ATLANTIS C3-H COATING





New design, more range, full manufacturing
The new approved high-performance anchors for direct fastening in cracked and non-cracked concrete are the most professional and effective solution. Its design allows quick and easy installation, guaranteeing maximum performance and higher load values compared to the previous version. The assortment of TH/TF anchors consists of different models of heads, suitable for installation in structural and non-structural elements such as railings, shelves or elements that need to be uninstalled or adjusted..
Range
HEXAGON HEAD.
ATLANTIS C3-H COATING
COUNTERSUNK HEAD.
ATLANTIS C3-H COATING
PAN HEAD.
ATLANTIS C3-H COATING
TRUSS HEAD.
ATLANTIS C3-H COATING
HEXAGON HEAD.
ZINC-PLATED COATING
HEXAGON HEAD WITHOUT WASHER.
ZINC-PLATED COATING
FIXING STUD.
ZINC-PLATED COATING
MALE THREAD HEAD.
ZINC-PLATED COATING
FEMALE THREAD HEAD.
ZINC-PLATED COATING
Patented double thread, optimised to guarantee maximum loads thanks to the design of a double thread that is embedded deep into the concrete.
The tempered tip ensures greater hardness, durability and ease of installation.
Body of high-resistance steel (stamped carbon steel).
THE/TFE Head: Embossed ribbed washer in hexagonal versions, which ensures a tightness against the base material, preventing the fastening from loosening.
TFF Head. Female thread with double M8/M10 thread, for direct, quick and easy fastening of threaded rods in ceilings (concrete and hollow-core slabs). Suitable for suspension of air conditioning ducts, cable trays, pipe systems, etc.
TFM Head. Male thread, for direct, quick and easy fastening of clamps in concrete and hollow-core slabs.
Head: Includes measurement by length (not in the diameter 5 ones).
We increased the maximum recommended loads in C20/25 uncracked concrete and C20/25 cracked concrete compared to the previous model.
Zinc-plated and Atlantis
C1 | C2 | C3 | C4 | C5 | |
---|---|---|---|---|---|
![]() |
![]() |
||||
|
|||||
|
|||||
|
|||||
|
|||||
|
|||||
|
|||||
|
|||||
|
THE 10 x 100 (example)
Installation | Fig. 1 | Fig. 2 | Fig. 3 |
---|---|---|---|
hnom Installation depth | 85 mm | 75 mm | 55 mm |
Nrec Maximum tensile load recommended * | 1.342 kg | 1.095 kg | 654 kg |
Tfix Maximum fixture thickness | 15 mm | 25 mm | 45 mm |
Applications
Installation guide
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6