a perfect fixing for your business

Through bolt anchor for uncracked concrete MTH-AT

Anchor for high loads in non-cracked concrete. Through bolt anchor, torque-controlled expansion. ETE Opt. 7 for structural applications in non-cracked concrete. Shaft and clip made of ATLANTIS C4-M steel.

ASSESSMENTS AND CERTIFICATES

CODESIZETHICKNESS MAX.FIXTURE (mm)AXIS LETTER (LENGTH)Pcs BoxPcs MasterboxEANTechnical info.
AHAT06060M6 x 60 Ø62B2001.2008423533894908
  • tfix - Max. fixture thickness2
  • SW - Installation key10
  • df - Ø Element to fix7
  • Tins - Torque (Nm)7
  • hef - Effective depth40
  • hnom - Min. anchor depth50
  • h1 - Drill hole depth min.55
  • d0 - Ø Drill6
  • hmin - Min. substrate thickness100
AHAT06080M6 x 80 Ø622D2001.2008423533895523
  • tfix - Max. fixture thickness22
  • SW - Installation key10
  • df - Ø Element to fix7
  • Tins - Torque (Nm)7
  • hef - Effective depth40
  • hnom - Min. anchor depth50
  • h1 - Drill hole depth min.55
  • d0 - Ø Drill6
  • hmin - Min. substrate thickness100
AHAT06100M6 x 100 Ø642E2008008423533895547
  • tfix - Max. fixture thickness42
  • SW - Installation key10
  • df - Ø Element to fix7
  • Tins - Torque (Nm)7
  • hef - Effective depth40
  • hnom - Min. anchor depth50
  • h1 - Drill hole depth min.55
  • d0 - Ø Drill6
  • hmin - Min. substrate thickness100
AHAT08060M8 x 60 Ø83B1006008423533895578
  • tfix - Max. fixture thickness3
  • SW - Installation key13
  • df - Ø Element to fix9
  • Tins - Torque (Nm)20
  • hef - Effective depth35
  • hnom - Min. anchor depth50
  • h1 - Drill hole depth min.50
  • d0 - Ø Drill8
  • hmin - Min. substrate thickness100
AHAT08075M8 x 75 Ø85C1006008423533895608
  • tfix - Max. fixture thickness5
  • SW - Installation key13
  • df - Ø Element to fix9
  • Tins - Torque (Nm)20
  • hef - Effective depth48
  • hnom - Min. anchor depth60
  • h1 - Drill hole depth min.65
  • d0 - Ø Drill8
  • hmin - Min. substrate thickness100
AHAT08090M8 x 90 Ø820E1006008423533895622
  • tfix - Max. fixture thickness20
  • SW - Installation key13
  • df - Ø Element to fix9
  • Tins - Torque (Nm)20
  • hef - Effective depth48
  • hnom - Min. anchor depth60
  • h1 - Drill hole depth min.65
  • d0 - Ø Drill8
  • hmin - Min. substrate thickness100
AHAT08115M8 x 115 Ø845G1004008423533895639
  • tfix - Max. fixture thickness45
  • SW - Installation key13
  • df - Ø Element to fix9
  • Tins - Torque (Nm)20
  • hef - Effective depth48
  • hnom - Min. anchor depth60
  • h1 - Drill hole depth min.65
  • d0 - Ø Drill8
  • hmin - Min. substrate thickness100
AHAT08130M8 x 130 Ø860H1004008423533895660
  • tfix - Max. fixture thickness60
  • SW - Installation key13
  • df - Ø Element to fix9
  • Tins - Torque (Nm)20
  • hef - Effective depth48
  • hnom - Min. anchor depth60
  • h1 - Drill hole depth min.65
  • d0 - Ø Drill8
  • hmin - Min. substrate thickness100
AHAT08155M8 x 155 Ø885J1002008423533895912
  • tfix - Max. fixture thickness85
  • SW - Installation key13
  • df - Ø Element to fix9
  • Tins - Torque (Nm)20
  • hef - Effective depth48
  • hnom - Min. anchor depth60
  • h1 - Drill hole depth min.65
  • d0 - Ø Drill8
  • hmin - Min. substrate thickness100
AHAT10070M10 x 70 Ø103C1004008423533895929
  • tfix - Max. fixture thickness3
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)35
  • hef - Effective depth42
  • hnom - Min. anchor depth54
  • h1 - Drill hole depth min.60
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness100
AHAT10080M10 x 80 Ø1013D1004008423533895936
  • tfix - Max. fixture thickness13
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)35
  • hef - Effective depth42
  • hnom - Min. anchor depth54
  • h1 - Drill hole depth min.60
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness100
AHAT10090M10 x 90 Ø1010E1004008423533895943
  • tfix - Max. fixture thickness10
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)35
  • hef - Effective depth55
  • hnom - Min. anchor depth67
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness110
AHAT10100M10 x 100 Ø1020E1004008423533895950
  • tfix - Max. fixture thickness20
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)35
  • hef - Effective depth55
  • hnom - Min. anchor depth67
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness110
AHAT10120M10 x 120 Ø1040G503008423533895967
  • tfix - Max. fixture thickness40
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)35
  • hef - Effective depth55
  • hnom - Min. anchor depth67
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness110
AHAT10140M10 x 140 Ø1060H502008423533895974
  • tfix - Max. fixture thickness60
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)35
  • hef - Effective depth55
  • hnom - Min. anchor depth67
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness110
AHAT10150M10 x 150 Ø1070I502008423533895981
  • tfix - Max. fixture thickness70
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)35
  • hef - Effective depth55
  • hnom - Min. anchor depth67
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness110
AHAT10160M10 x 160 Ø1080J502008423533895998
  • tfix - Max. fixture thickness80
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)35
  • hef - Effective depth55
  • hnom - Min. anchor depth67
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness110
AHAT10170M10 x 170 Ø1090K502008423533896001
  • tfix - Max. fixture thickness90
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)35
  • hef - Effective depth55
  • hnom - Min. anchor depth67
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness110
AHAT10210M10 x 210 Ø10130N501508423533896018
  • tfix - Max. fixture thickness130
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)35
  • hef - Effective depth55
  • hnom - Min. anchor depth67
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness110
AHAT12090M12 x 90 Ø1213E502008423533896025
  • tfix - Max. fixture thickness13
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth50
  • hnom - Min. anchor depth60
  • h1 - Drill hole depth min.70
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness100
AHAT12100M12 x 100 Ø128E502008423533896032
  • tfix - Max. fixture thickness8
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth65
  • hnom - Min. anchor depth77
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness130
AHAT12110M12 x 110 Ø1218F502008423533896049
  • tfix - Max. fixture thickness18
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth65
  • hnom - Min. anchor depth77
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness130
AHAT12130M12 x 130 Ø1238H502008423533896056
  • tfix - Max. fixture thickness38
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth65
  • hnom - Min. anchor depth77
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness130
AHAT12140M12 x 140 Ø1248H502008423533896063
  • tfix - Max. fixture thickness48
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth65
  • hnom - Min. anchor depth77
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness130
AHAT12160M12 x 160 Ø1268J501008423533896070
  • tfix - Max. fixture thickness68
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth65
  • hnom - Min. anchor depth77
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness130
AHAT12180M12 x 180 Ø1288L501508423533896094
  • tfix - Max. fixture thickness88
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth65
  • hnom - Min. anchor depth77
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness130
AHAT12200M12 x 200 Ø12108M501008423533896124
  • tfix - Max. fixture thickness108
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth65
  • hnom - Min. anchor depth77
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness130
AHAT12220M12 x 220 Ø12128O501008423533896155
  • tfix - Max. fixture thickness128
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth65
  • hnom - Min. anchor depth77
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness130
AHAT12250M12 x 250 Ø12158Q25508423533896216
  • tfix - Max. fixture thickness158
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth65
  • hnom - Min. anchor depth77
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness130
AHAT16125M16 x 125 Ø163G251008423533896223
  • tfix - Max. fixture thickness3
  • SW - Installation key24
  • df - Ø Element to fix18
  • Tins - Torque (Nm)120
  • hef - Effective depth84
  • hnom - Min. anchor depth104
  • h1 - Drill hole depth min.110
  • d0 - Ø Drill16
  • hmin - Min. substrate thickness168
AHAT16145M16 x 145 Ø1623I251008423533896230
  • tfix - Max. fixture thickness23
  • SW - Installation key24
  • df - Ø Element to fix18
  • Tins - Torque (Nm)120
  • hef - Effective depth84
  • hnom - Min. anchor depth104
  • h1 - Drill hole depth min.110
  • d0 - Ø Drill16
  • hmin - Min. substrate thickness168
AHAT16170M16 x 170 Ø1648K25508423533896896
  • tfix - Max. fixture thickness48
  • SW - Installation key24
  • df - Ø Element to fix18
  • Tins - Torque (Nm)120
  • hef - Effective depth84
  • hnom - Min. anchor depth104
  • h1 - Drill hole depth min.110
  • d0 - Ø Drill16
  • hmin - Min. substrate thickness168
AHAT16220M16 x 220 Ø1698O25508423533896247
  • tfix - Max. fixture thickness98
  • SW - Installation key24
  • df - Ø Element to fix18
  • Tins - Torque (Nm)120
  • hef - Effective depth84
  • hnom - Min. anchor depth104
  • h1 - Drill hole depth min.110
  • d0 - Ø Drill16
  • hmin - Min. substrate thickness168
AHAT16250M16 x 250 Ø16128Q25508423533896254
  • tfix - Max. fixture thickness128
  • SW - Installation key24
  • df - Ø Element to fix18
  • Tins - Torque (Nm)120
  • hef - Effective depth84
  • hnom - Min. anchor depth104
  • h1 - Drill hole depth min.110
  • d0 - Ø Drill16
  • hmin - Min. substrate thickness168
AHAT16280M16 x 280 Ø16158S25508423533896261
  • tfix - Max. fixture thickness158
  • SW - Installation key24
  • df - Ø Element to fix18
  • Tins - Torque (Nm)120
  • hef - Effective depth84
  • hnom - Min. anchor depth104
  • h1 - Drill hole depth min.110
  • d0 - Ø Drill16
  • hmin - Min. substrate thickness168
AHAT20170M20 x 170 Ø2023K20408423533896278
  • tfix - Max. fixture thickness23
  • SW - Installation key30
  • df - Ø Element to fix22
  • Tins - Torque (Nm)240
  • hef - Effective depth103
  • hnom - Min. anchor depth125
  • h1 - Drill hole depth min.135
  • d0 - Ø Drill20
  • hmin - Min. substrate thickness206
AHAT20220M20 x 220 Ø2073O20408423533896285
  • tfix - Max. fixture thickness73
  • SW - Installation key30
  • df - Ø Element to fix22
  • Tins - Torque (Nm)240
  • hef - Effective depth103
  • hnom - Min. anchor depth125
  • h1 - Drill hole depth min.135
  • d0 - Ø Drill20
  • hmin - Min. substrate thickness206
AHAT20270M20 x 270 Ø20123S20408423533896292
  • tfix - Max. fixture thickness123
  • SW - Installation key30
  • df - Ø Element to fix22
  • Tins - Torque (Nm)240
  • hef - Effective depth103
  • hnom - Min. anchor depth125
  • h1 - Drill hole depth min.135
  • d0 - Ø Drill20
  • hmin - Min. substrate thickness206
Suitable for indoor climbing equipment without corrosion. M12 recommended. Recommendations are according to UNE EN:959 2021.
No hay aplicaciones disponibles para este producto.
MTH-AT
icon book
Technical Sheets
icon table
Declaration of Performances
DoP_MTH_en_rev5.pdf

related products

Request more information

TÉCNICAS EXPANSIVAS S.L. informs that the personal data provided voluntarily on this website will be processed and incorporated into the corresponding files, responsibility of TÉCNICAS EXPANSIVAS S.L, is reported at the time of personal data collection, although, according to the specific case, its purpose may be any of the following: attention to your referred request, complaint or question, established relationship maintenance, comprehensive and commercial customer management, accounting and billing or sending communications, including electronic media, news and activities related to TÉCNICAS EXPANSIVAS S.L.

The data in our files are strictly confidential and shall be treated with the utmost confidentiality and shall comply with all the requirements provided for the General Data Protection Regulation (GDPR) 2016.

According to Data Protection legislation, you are strongly advised not to send high-level personal data, such as those relating to health, as they are not encoded or encrypted. Should these details be sent, it is done so under your sole responsibility.

The user may at any time exercise their rights of access, rectification, cancellation and opposition under the provisions of the General Data Protection Regulation (GDPR) 2016 by sending a letter together with a photocopy of your ID, to P.I. La Portalada II | c/ Segador 13, 26006 | Logroño (La Rioja).
Read more
MTH-AT

MTH-AT

Opt.7 ETA Assessed. ATLANTIS C4-M shaft. ATLANTIS C4-M clip
Metal fixings
Chemical fixings
Plastic fixings
Fixings and accessories for thermal insulation systems (ETICS)
Fixings & accesories for plasterboard
Rivets
Rigging hardware
Fixings & accesories for Drywall
Direct fixing
Screws for decking and façades
Drill, tapping and PVC screws
Wood screws
Nails and bolts
Wood connectors
Standardized nuts and bolts
Plugs, tips and accessories
Heavy metal clamps
Light metal clamps
Fire protection systems
Gutter supports
Plastic clamps
Profiles and supports
Installation systems and fixings for solar panels
Quick beam attachament system
Threaded rod and fixing accesories
Bathroom and air conditioning fixings
DIY

TECHNICAL TRAINING

Our engineering department provides specific and personalised training on the different topics related to fixing systems: metallic or chemical fixings, installation systems, regulations, calculations, etc.

 

TÉCNICAS EXPANSIVAS S.L. informs that the personal data provided voluntarily on this website will be processed and incorporated into the corresponding files, responsibility of TÉCNICAS EXPANSIVAS S.L, is reported at the time of personal data collection, although, according to the specific case, its purpose may be any of the following: attention to your referred request, complaint or question, established relationship maintenance, comprehensive and commercial customer management, accounting and billing or sending communications, including electronic media, news and activities related to TÉCNICAS EXPANSIVAS S.L.

The data in our files are strictly confidential and shall be treated with the utmost confidentiality and shall comply with all the requirements provided for the General Data Protection Regulation (GDPR) 2016.

According to Data Protection legislation, you are strongly advised not to send high-level personal data, such as those relating to health, as they are not encoded or encrypted. Should these details be sent, it is done so under your sole responsibility.

The user may at any time exercise their rights of access, rectification, cancellation and opposition under the provisions of the General Data Protection Regulation (GDPR) 2016 by sending a letter together with a photocopy of your ID, to P.I. La Portalada II | c/ Segador 13, 26006 | Logroño (La Rioja).
Read more

site visits

The relationship with our customers does not end with the sale of our products. At INDEX® we understand that it is often necessary to accompany them on site, where our experience is the best ally to ensure fits works perfectly. Our engineers and technicians support the managers of each project in planning and selecting the best solution for effectively saving time and money.

TÉCNICAS EXPANSIVAS S.L. informs that the personal data provided voluntarily on this website will be processed and incorporated into the corresponding files, responsibility of TÉCNICAS EXPANSIVAS S.L, is reported at the time of personal data collection, although, according to the specific case, its purpose may be any of the following: attention to your referred request, complaint or question, established relationship maintenance, comprehensive and commercial customer management, accounting and billing or sending communications, including electronic media, news and activities related to TÉCNICAS EXPANSIVAS S.L.

The data in our files are strictly confidential and shall be treated with the utmost confidentiality and shall comply with all the requirements provided for the General Data Protection Regulation (GDPR) 2016.

According to Data Protection legislation, you are strongly advised not to send high-level personal data, such as those relating to health, as they are not encoded or encrypted. Should these details be sent, it is done so under your sole responsibility.

The user may at any time exercise their rights of access, rectification, cancellation and opposition under the provisions of the General Data Protection Regulation (GDPR) 2016 by sending a letter together with a photocopy of your ID, to P.I. La Portalada II | c/ Segador 13, 26006 | Logroño (La Rioja).
Read more

ENGINEERING SERVICES AND CALCULATIONS

TÉCNICAS EXPANSIVAS S.L. informs that the personal data provided voluntarily on this website will be processed and incorporated into the corresponding files, responsibility of TÉCNICAS EXPANSIVAS S.L, is reported at the time of personal data collection, although, according to the specific case, its purpose may be any of the following: attention to your referred request, complaint or question, established relationship maintenance, comprehensive and commercial customer management, accounting and billing or sending communications, including electronic media, news and activities related to TÉCNICAS EXPANSIVAS S.L.

The data in our files are strictly confidential and shall be treated with the utmost confidentiality and shall comply with all the requirements provided for the General Data Protection Regulation (GDPR) 2016.

According to Data Protection legislation, you are strongly advised not to send high-level personal data, such as those relating to health, as they are not encoded or encrypted. Should these details be sent, it is done so under your sole responsibility.

The user may at any time exercise their rights of access, rectification, cancellation and opposition under the provisions of the General Data Protection Regulation (GDPR) 2016 by sending a letter together with a photocopy of your ID, to P.I. La Portalada II | c/ Segador 13, 26006 | Logroño (La Rioja).
Read more