a perfect fixing for your business

Assessed through bolt anchor MTP

Through bolt anchor for high loads in cracked and non-cracked concrete. It works by controlled torque expansion, zinc plated steel shaft and A4 stainless steel clip, ETE Opt.1 approved, which ensures its performance in structural fastenings on concrete.

ASSESSMENTS AND CERTIFICATES

CODESIZETHICKNESS MAX.FIXTURE (mm)AXIS LETTER (LENGTH)Pcs BoxPcs MasterboxEANTechnical info.
AP08050M8 x 50 Ø82A1008008423533710505
  • tfix - Max. fixture thickness2
  • SW - Installation key13
  • df - Ø Element to fix9
  • Tins - Torque (Nm)20
  • hef - Effective depth30
  • hnom - Min. anchor depth37
  • h1 - Drill hole depth min.40
  • d0 - Ø Drill8
  • hmin - Min. substrate thickness100
AP08075M8 x 75 Ø89C1006008423533710512
  • tfix - Max. fixture thickness9
  • SW - Installation key13
  • df - Ø Element to fix9
  • Tins - Torque (Nm)20
  • hef - Effective depth48
  • hnom - Min. anchor depth55
  • h1 - Drill hole depth min.60
  • d0 - Ø Drill8
  • hmin - Min. substrate thickness100
AP08095M8 x 95 Ø829E1006008423533710529
  • tfix - Max. fixture thickness29
  • SW - Installation key13
  • df - Ø Element to fix9
  • Tins - Torque (Nm)20
  • hef - Effective depth48
  • hnom - Min. anchor depth55
  • h1 - Drill hole depth min.60
  • d0 - Ø Drill8
  • hmin - Min. substrate thickness100
AP08115M8 x 115 Ø849G1004008423533710536
  • tfix - Max. fixture thickness49
  • SW - Installation key13
  • df - Ø Element to fix9
  • Tins - Torque (Nm)20
  • hef - Effective depth48
  • hnom - Min. anchor depth55
  • h1 - Drill hole depth min.60
  • d0 - Ø Drill8
  • hmin - Min. substrate thickness100
AP10090M10 x 90 Ø1010E1004008423533710543
  • tfix - Max. fixture thickness10
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)40
  • hef - Effective depth60
  • hnom - Min. anchor depth68
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness120
AP10105M10 x 105 Ø1025F503008423533710550
  • tfix - Max. fixture thickness25
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)40
  • hef - Effective depth60
  • hnom - Min. anchor depth68
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness120
AP10115M10 x 115 Ø1035G502008423533710567
  • tfix - Max. fixture thickness35
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)40
  • hef - Effective depth60
  • hnom - Min. anchor depth68
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness120
AP10135M10 x 135 Ø1055H502008423533710574
  • tfix - Max. fixture thickness55
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)40
  • hef - Effective depth60
  • hnom - Min. anchor depth68
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness120
AP10165M10 x 165 Ø1085K502008423533710581
  • tfix - Max. fixture thickness85
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)40
  • hef - Effective depth60
  • hnom - Min. anchor depth68
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness120
AP10185M10 x 185 Ø10105L501508423533710598
  • tfix - Max. fixture thickness105
  • SW - Installation key17
  • df - Ø Element to fix12
  • Tins - Torque (Nm)40
  • hef - Effective depth60
  • hnom - Min. anchor depth68
  • h1 - Drill hole depth min.75
  • d0 - Ø Drill10
  • hmin - Min. substrate thickness120
AP12080M12 x 80 Ø124D503008423533710604
  • tfix - Max. fixture thickness4
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth50
  • hnom - Min. anchor depth60
  • h1 - Drill hole depth min.65
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness100
AP12100M12 x 100 Ø124E502008423533749932
  • tfix - Max. fixture thickness4
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth70
  • hnom - Min. anchor depth80
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness140
AP12110M12 x 110 Ø1214F502008423533710611
  • tfix - Max. fixture thickness14
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth70
  • hnom - Min. anchor depth80
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness140
AP12120M12 x 120 Ø1224G502008423533710628
  • tfix - Max. fixture thickness24
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth70
  • hnom - Min. anchor depth80
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness140
AP12130M12 x 130 Ø1234H502008423533710635
  • tfix - Max. fixture thickness34
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth70
  • hnom - Min. anchor depth80
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness140
AP12150M12 x 150 Ø1254I501008423533710642
  • tfix - Max. fixture thickness54
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth70
  • hnom - Min. anchor depth80
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness140
AP12180M12 x 180 Ø1284L501508423533710659
  • tfix - Max. fixture thickness84
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth70
  • hnom - Min. anchor depth80
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness140
AP12200M12 x 200 Ø12104M501508423533710666
  • tfix - Max. fixture thickness104
  • SW - Installation key19
  • df - Ø Element to fix14
  • Tins - Torque (Nm)60
  • hef - Effective depth70
  • hnom - Min. anchor depth80
  • h1 - Drill hole depth min.85
  • d0 - Ø Drill12
  • hmin - Min. substrate thickness140
AP16145M16 x 145 Ø1628I251008423533710673
  • tfix - Max. fixture thickness28
  • SW - Installation key24
  • df - Ø Element to fix18
  • Tins - Torque (Nm)100
  • hef - Effective depth85
  • hnom - Min. anchor depth97
  • h1 - Drill hole depth min.105
  • d0 - Ø Drill16
  • hmin - Min. substrate thickness170
AP16175M16 x 175 Ø1658K25508423533710680
  • tfix - Max. fixture thickness58
  • SW - Installation key24
  • df - Ø Element to fix18
  • Tins - Torque (Nm)100
  • hef - Effective depth85
  • hnom - Min. anchor depth97
  • h1 - Drill hole depth min.105
  • d0 - Ø Drill16
  • hmin - Min. substrate thickness170
AP16220M16 x 220 Ø16103O25508423533710697
  • tfix - Max. fixture thickness103
  • SW - Installation key24
  • df - Ø Element to fix18
  • Tins - Torque (Nm)100
  • hef - Effective depth85
  • hnom - Min. anchor depth97
  • h1 - Drill hole depth min.105
  • d0 - Ø Drill16
  • hmin - Min. substrate thickness170
AP16250M16 x 250 Ø16133Q25508423533710703
  • tfix - Max. fixture thickness133
  • SW - Installation key24
  • df - Ø Element to fix18
  • Tins - Torque (Nm)100
  • hef - Effective depth85
  • hnom - Min. anchor depth97
  • h1 - Drill hole depth min.105
  • d0 - Ø Drill16
  • hmin - Min. substrate thickness170
AP20170M20 x 170 Ø2032K20408423533710710
  • tfix - Max. fixture thickness32
  • SW - Installation key30
  • df - Ø Element to fix22
  • Tins - Torque (Nm)200
  • hef - Effective depth100
  • hnom - Min. anchor depth114
  • h1 - Drill hole depth min.125
  • d0 - Ø Drill20
  • hmin - Min. substrate thickness200
AP20200M20 x 200 Ø2062N20408423533710727
  • tfix - Max. fixture thickness62
  • SW - Installation key30
  • df - Ø Element to fix22
  • Tins - Torque (Nm)200
  • hef - Effective depth100
  • hnom - Min. anchor depth114
  • h1 - Drill hole depth min.125
  • d0 - Ø Drill20
  • hmin - Min. substrate thickness200
AP24205M24 x 205 Ø2435N10308423533783738
  • tfix - Max. fixture thickness35
  • SW - Installation key36
  • df - Ø Element to fix26
  • Tins - Torque (Nm)250
  • hef - Effective depth125
  • hnom - Min. anchor depth143
  • h1 - Drill hole depth min.155
  • d0 - Ø Drill24
  • hmin - Min. substrate thickness250
AP24235M24 x 235 Ø2465P10208423533783745
  • tfix - Max. fixture thickness65
  • SW - Installation key36
  • df - Ø Element to fix26
  • Tins - Torque (Nm)250
  • hef - Effective depth125
  • hnom - Min. anchor depth143
  • h1 - Drill hole depth min.155
  • d0 - Ø Drill24
  • hmin - Min. substrate thickness250
  • Fixing of shelves
  • Steel structures
  • Protections
  • Street furniture
  • Machinery
  • Wooden structures
  • Antennae
  • Balcony railings
  • Road railings
  • Wooden railings
  • Beach railings
  • Ceiling lights
  • False ceilings
  • False ceilings
  • Ceiling lights
  • False ceilings
  • Ceiling lights
  • False ceilings
  • Ceilings
  • Ceilings
  • Ceilings
  • Ceilings
  • Ceilings
  • Ceilings
MTP
icon book
Technical Sheets
icon camera
Multimedia
icon table
Declaration of Performances
DoP_MTP_en_rev9.pdf

related products

Request more information

TÉCNICAS EXPANSIVAS S.L. informs that the personal data provided voluntarily on this website will be processed and incorporated into the corresponding files, responsibility of TÉCNICAS EXPANSIVAS S.L, is reported at the time of personal data collection, although, according to the specific case, its purpose may be any of the following: attention to your referred request, complaint or question, established relationship maintenance, comprehensive and commercial customer management, accounting and billing or sending communications, including electronic media, news and activities related to TÉCNICAS EXPANSIVAS S.L.

The data in our files are strictly confidential and shall be treated with the utmost confidentiality and shall comply with all the requirements provided for the General Data Protection Regulation (GDPR) 2016.

According to Data Protection legislation, you are strongly advised not to send high-level personal data, such as those relating to health, as they are not encoded or encrypted. Should these details be sent, it is done so under your sole responsibility.

The user may at any time exercise their rights of access, rectification, cancellation and opposition under the provisions of the General Data Protection Regulation (GDPR) 2016 by sending a letter together with a photocopy of your ID, to P.I. La Portalada II | c/ Segador 13, 26006 | Logroño (La Rioja).
Read more
MTP

MTP

Opt.1 ETA Assessed. Zinc-plated shaft. A4 stainless clip
Metal fixings
Chemical fixings
Plastic fixings
Fixings and accessories for thermal insulation systems (ETICS)
Fixings & accesories for plasterboard
Rivets
Rigging hardware
Fixings & accesories for Drywall
Direct fixing
Screws for decking and façades
Drill, tapping and PVC screws
Wood screws
Nails and bolts
Wood connectors
Standardized nuts and bolts
Plugs, tips and accessories
Heavy metal clamps
Light metal clamps
Fire protection systems
Gutter supports
Plastic clamps
Profiles and supports
Installation systems and fixings for solar panels
Quick beam attachament system
Threaded rod and fixing accesories
Bathroom and air conditioning fixings
DIY

TECHNICAL TRAINING

Our engineering department provides specific and personalised training on the different topics related to fixing systems: metallic or chemical fixings, installation systems, regulations, calculations, etc.

 

TÉCNICAS EXPANSIVAS S.L. informs that the personal data provided voluntarily on this website will be processed and incorporated into the corresponding files, responsibility of TÉCNICAS EXPANSIVAS S.L, is reported at the time of personal data collection, although, according to the specific case, its purpose may be any of the following: attention to your referred request, complaint or question, established relationship maintenance, comprehensive and commercial customer management, accounting and billing or sending communications, including electronic media, news and activities related to TÉCNICAS EXPANSIVAS S.L.

The data in our files are strictly confidential and shall be treated with the utmost confidentiality and shall comply with all the requirements provided for the General Data Protection Regulation (GDPR) 2016.

According to Data Protection legislation, you are strongly advised not to send high-level personal data, such as those relating to health, as they are not encoded or encrypted. Should these details be sent, it is done so under your sole responsibility.

The user may at any time exercise their rights of access, rectification, cancellation and opposition under the provisions of the General Data Protection Regulation (GDPR) 2016 by sending a letter together with a photocopy of your ID, to P.I. La Portalada II | c/ Segador 13, 26006 | Logroño (La Rioja).
Read more

site visits

The relationship with our customers does not end with the sale of our products. At INDEX® we understand that it is often necessary to accompany them on site, where our experience is the best ally to ensure fits works perfectly. Our engineers and technicians support the managers of each project in planning and selecting the best solution for effectively saving time and money.

TÉCNICAS EXPANSIVAS S.L. informs that the personal data provided voluntarily on this website will be processed and incorporated into the corresponding files, responsibility of TÉCNICAS EXPANSIVAS S.L, is reported at the time of personal data collection, although, according to the specific case, its purpose may be any of the following: attention to your referred request, complaint or question, established relationship maintenance, comprehensive and commercial customer management, accounting and billing or sending communications, including electronic media, news and activities related to TÉCNICAS EXPANSIVAS S.L.

The data in our files are strictly confidential and shall be treated with the utmost confidentiality and shall comply with all the requirements provided for the General Data Protection Regulation (GDPR) 2016.

According to Data Protection legislation, you are strongly advised not to send high-level personal data, such as those relating to health, as they are not encoded or encrypted. Should these details be sent, it is done so under your sole responsibility.

The user may at any time exercise their rights of access, rectification, cancellation and opposition under the provisions of the General Data Protection Regulation (GDPR) 2016 by sending a letter together with a photocopy of your ID, to P.I. La Portalada II | c/ Segador 13, 26006 | Logroño (La Rioja).
Read more

ENGINEERING SERVICES AND CALCULATIONS

TÉCNICAS EXPANSIVAS S.L. informs that the personal data provided voluntarily on this website will be processed and incorporated into the corresponding files, responsibility of TÉCNICAS EXPANSIVAS S.L, is reported at the time of personal data collection, although, according to the specific case, its purpose may be any of the following: attention to your referred request, complaint or question, established relationship maintenance, comprehensive and commercial customer management, accounting and billing or sending communications, including electronic media, news and activities related to TÉCNICAS EXPANSIVAS S.L.

The data in our files are strictly confidential and shall be treated with the utmost confidentiality and shall comply with all the requirements provided for the General Data Protection Regulation (GDPR) 2016.

According to Data Protection legislation, you are strongly advised not to send high-level personal data, such as those relating to health, as they are not encoded or encrypted. Should these details be sent, it is done so under your sole responsibility.

The user may at any time exercise their rights of access, rectification, cancellation and opposition under the provisions of the General Data Protection Regulation (GDPR) 2016 by sending a letter together with a photocopy of your ID, to P.I. La Portalada II | c/ Segador 13, 26006 | Logroño (La Rioja).
Read more