A PERFECT FIXING FOR YOUR BUSINESS
(+34) 941.272.131
MTH - Through bolt anchor for heavy loads in uncracked concrete.
MTH - Through bolt anchor for heavy loads in uncracked concrete.
MTH - Through bolt anchor for heavy loads in uncracked concrete.
Youtube 1 - MTH - Through bolt anchor for heavy loads in uncracked concrete.
MTH - Through bolt anchor for heavy loads in uncracked concrete.
MTH - Through bolt anchor for heavy loads in uncracked concrete.
Youtube 1 - MTH - Through bolt anchor for heavy loads in uncracked concrete.

Metal fixings - MTH

MTH

Through bolt anchor for heavy loads in uncracked concrete. Opt.7 ETA Assessed. Zinc-plated shaft. Zinc-plated clip.

Amplify information

  • Fixing of shelves
  • Steel structures
  • Protections
  • Street furniture
  • Machinery
  • Wooden structures
  • Antennae
  • Balcony railings
  • Road railings
  • Wooden railings
  • Beach railings
  • Ceiling lights
  • False ceilings
  • False ceilings
  • Ceiling lights
  • False ceilings
  • Ceiling lights
  • False ceilings
  • Ceilings
  • Ceilings
  • Ceilings
  • Ceilings
  • Ceilings
  • Ceilings
MTH - Through bolt anchor for heavy loads in uncracked concrete.
Installation - MTH - Through bolt anchor for heavy loads in uncracked concrete.
Concrete

Concrete

Reinforced concrete

Reinforced concrete

Stone

Stone

Code Dimension €/100€/Bag Professional boxPieces/LS bag MasterboxBags/Box LS EAN technical info.
AH06060 M6 x 60 Ø6 49,390 200 1.200 8423533574909
L - Length 60
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 2
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH06070 M6 x 70 Ø6 51,273 200 1.200 8423533574916
L - Length 70
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 12
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH06080 M6 x 80 Ø6 53,150 200 1.200 8423533574923
L - Length 80
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 22
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH06090 M6 x 90 Ø6 54,770 200 1.200 8423533574930
L - Length 90
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 32
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH06100 M6 x 100 Ø6 57,053 200 800 8423533574947
L - Length 100
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 42
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH06110 M6 x 110 Ø6 74,390 200 800 8423533574954
L - Length 110
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 52
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH06120 M6 x 120 Ø6 78,100 100 600 8423533574961
L - Length 120
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 62
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH06130 M6 x 130 Ø6 90,347 100 600 8423533574978
L - Length 130
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 72
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH06140 M6 x 140 Ø6 90,990 100 400 8423533574985
L - Length 140
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 82
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH06150 M6 x 150 Ø6 93,367 100 400 8423533574992
L - Length 150
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 92
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH06160 M6 x 160 Ø6 100,590 100 400 8423533575005
L - Length 160
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 102
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH06170 M6 x 170 Ø6 114,057 100 400 8423533575012
L - Length 170
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 112
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH06180 M6 x 180 Ø6 125,307 100 200 8423533575029
L - Length 180
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 122
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
AH08060 M8 x 60 Ø8 61,133 100 600 8423533684912
L - Length 60
d0 - Ø Broca 8
hnom - Min. anchor depth 50
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 3
Min. distance to edge “A” 53
SW - Installation key 13
Shear load non-cracked concrete 494
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 35
Tins - Torque (Nm) 20
Min. distance from axis "B" 105
Tension load non-cracked concrete 485
AH08075 M8 x 75 Ø8 64,637 100 600 8423533575036
L - Length 75
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 5
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 542
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 676
AH08090 M8 x 90 Ø8 70,073 100 600 8423533575043
L - Length 90
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 20
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 542
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 676
AH08100 M8 x 100 Ø8 74,767 100 400 8423533749956
L - Length 100
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 30
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 542
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 676
AH08115 M8 x 115 Ø8 87,723 100 400 8423533575050
L - Length 115
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 45
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 542
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 676
AH08120 M8 x 120 Ø8 96,000 100 400 8423533041661
L - Length 120
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 50
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 542
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 676
AH08130 M8 x 130 Ø8 101,080 100 400 8423533575067
L - Length 130
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 60
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 542
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 676
AH08155 M8 x 155 Ø8 153,330 100 200 8423533575074
L - Length 155
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 85
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 542
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 676
AH10070 M10 x 70 Ø10 80,047 100 400 8423533684714
L - Length 70
d0 - Ø Broca 10
hnom - Min. anchor depth 60
h1 - Drill hole depth min. 54
tfix - Max. fixture thickness 3
Min. distance to edge “A” 63
SW - Installation key 17
Shear load non-cracked concrete 650
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 100
hef - Effective depth 42
Tins - Torque (Nm) 35
Min. distance from axis "B" 126
Tension load non-cracked concrete 650
AH10080 M10 x 80 Ø10 91,533 100 400 8423533702166
L - Length 80
d0 - Ø Broca 10
hnom - Min. anchor depth 60
h1 - Drill hole depth min. 54
tfix - Max. fixture thickness 13
Min. distance to edge “A” 63
SW - Installation key 17
Shear load non-cracked concrete 650
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 100
hef - Effective depth 42
Tins - Torque (Nm) 35
Min. distance from axis "B" 126
Tension load non-cracked concrete 650
AH10090 M10 x 90 Ø10 95,437 100 400 8423533575081
L - Length 90
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 10
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 856
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 922
AH10100 M10 x 100 Ø10 110,043 100 400 8423533702173
L - Length 100
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 20
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 856
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 922
AH10120 M10 x 120 Ø10 115,460 50 300 8423533575098
L - Length 120
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 40
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 856
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 922
AH10140 M10 x 140 Ø10 144,337 50 200 8423533041760
L - Length 140
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 60
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 856
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 922
AH10150 M10 x 150 Ø10 150,153 50 200 8423533575104
L - Length 150
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 70
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 856
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 922
AH10160 M10 x 160 Ø10 170,987 50 200 8423533041821
L - Length 160
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 80
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 856
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 922
AH10170 M10 x 170 Ø10 190,673 50 200 8423533575111
L - Length 170
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 90
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 856
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 922
AH10210 M10 x 210 Ø10 230,677 50 150 8423533684929
L - Length 210
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 130
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 856
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 922
AH10230 M10 x 230 Ø10 244,677 50 100 8423533684936
L - Length 230
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 150
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 856
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 922
AH12090 M12 x 90 Ø12 131,247 50 200 8423533684943
L - Length 90
d0 - Ø Broca 12
hnom - Min. anchor depth 70
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 13
Min. distance to edge “A” 75
SW - Installation key 19
Shear load non-cracked concrete 844
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 100
hef - Effective depth 50
Tins - Torque (Nm) 60
Min. distance from axis "B" 150
Tension load non-cracked concrete 844
AH12100 M12 x 100 Ø12 141,860 50 200 8423533702197
L - Length 100
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 8
Min. distance to edge “A” 75
SW - Installation key 19
Shear load non-cracked concrete 1200
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 150
Tension load non-cracked concrete 1251
AH12110 M12 x 110 Ø12 146,770 50 200 8423533575128
L - Length 110
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 18
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1200
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1251
AH12120 M12 x 120 Ø12 182,097 50 200 8423533702203
L - Length 120
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 28
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1200
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1251
AH12130 M12 x 130 Ø12 189,847 50 200 8423533749994
L - Length 130
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 38
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1200
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1251
AH12140 M12 x 140 Ø12 190,283 50 200 8423533575135
L - Length 140
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 48
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1200
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1251
AH12160 M12 x 160 Ø12 223,617 50 100 8423533575142
L - Length 160
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 68
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1200
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1251
AH12180 M12 x 180 Ø12 260,020 50 150 8423533575159
L - Length 180
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 88
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1200
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1251
AH12200 M12 x 200 Ø12 303,650 50 100 8423533743374
L - Length 200
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 108
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1200
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1251
AH12220 M12 x 220 Ø12 329,547 50 100 8423533684950
L - Length 220
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 128
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1200
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1251
AH12250 M12 x 250 Ø12 402,853 25 50 8423533684967
L - Length 250
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 158
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1200
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1251
AH14120 M14 x 120 Ø14 314,270 25 100 8423533575166
L - Length 120
d0 - Ø Broca 14
hnom - Min. anchor depth 100
h1 - Drill hole depth min. 91
tfix - Max. fixture thickness 12
Min. distance to edge “A” 113
SW - Installation key 22
Shear load non-cracked concrete 1637
Mº - M M14
df - Ø Element to fix 16
hmin - Min. substrate thickness 150
hef - Effective depth 75
Tins - Torque (Nm) 90
Min. distance from axis "B" 225
Tension load non-cracked concrete 1551
AH14145 M14 x 145 Ø14 369,033 25 100 8423533575173
L - Length 145
d0 - Ø Broca 14
hnom - Min. anchor depth 100
h1 - Drill hole depth min. 91
tfix - Max. fixture thickness 37
Min. distance to edge “A” 113
SW - Installation key 22
Shear load non-cracked concrete 1637
Mº - M M14
df - Ø Element to fix 16
hmin - Min. substrate thickness 150
hef - Effective depth 75
Tins - Torque (Nm) 90
Min. distance from axis "B" 225
Tension load non-cracked concrete 1551
AH14170 M14 x 170 Ø14 394,260 25 100 8423533575180
L - Length 170
d0 - Ø Broca 14
hnom - Min. anchor depth 100
h1 - Drill hole depth min. 91
tfix - Max. fixture thickness 62
Min. distance to edge “A” 113
SW - Installation key 22
Shear load non-cracked concrete 1637
Mº - M M14
df - Ø Element to fix 16
hmin - Min. substrate thickness 150
hef - Effective depth 75
Tins - Torque (Nm) 90
Min. distance from axis "B" 225
Tension load non-cracked concrete 1551
AH14220 M14 x 220 Ø14 546,670 25 75 8423533684974
L - Length 220
d0 - Ø Broca 14
hnom - Min. anchor depth 100
h1 - Drill hole depth min. 91
tfix - Max. fixture thickness 112
Min. distance to edge “A” 113
SW - Installation key 22
Shear load non-cracked concrete 1637
Mº - M M14
df - Ø Element to fix 16
hmin - Min. substrate thickness 150
hef - Effective depth 75
Tins - Torque (Nm) 90
Min. distance from axis "B" 225
Tension load non-cracked concrete 1551
AH14250 M14 x 250 Ø14 610,630 25 50 8423533684981
L - Length 250
d0 - Ø Broca 14
hnom - Min. anchor depth 100
h1 - Drill hole depth min. 91
tfix - Max. fixture thickness 142
Min. distance to edge “A” 113
SW - Installation key 22
Shear load non-cracked concrete 1637
Mº - M M14
df - Ø Element to fix 16
hmin - Min. substrate thickness 150
hef - Effective depth 75
Tins - Torque (Nm) 90
Min. distance from axis "B" 225
Tension load non-cracked concrete 1551
AH16125 M16 x 125 Ø16 322,437 25 100 8423533575197
L - Length 125
d0 - Ø Broca 16
hnom - Min. anchor depth 110
h1 - Drill hole depth min. 104
tfix - Max. fixture thickness 3
Min. distance to edge “A” 126
SW - Installation key 24
Shear load non-cracked concrete 2237
Mº - M M16
df - Ø Element to fix 18
hmin - Min. substrate thickness 168
hef - Effective depth 84
Tins - Torque (Nm) 120
Min. distance from axis "B" 252
Tension load non-cracked concrete 1887
AH16145 M16 x 145 Ø16 347,447 25 100 8423533575203
L - Length 145
d0 - Ø Broca 16
hnom - Min. anchor depth 110
h1 - Drill hole depth min. 104
tfix - Max. fixture thickness 23
Min. distance to edge “A” 126
SW - Installation key 24
Shear load non-cracked concrete 2237
Mº - M M16
df - Ø Element to fix 18
hmin - Min. substrate thickness 168
hef - Effective depth 84
Tins - Torque (Nm) 120
Min. distance from axis "B" 252
Tension load non-cracked concrete 1887
AH16170 M16 x 170 Ø16 429,667 25 50 8423533575210
L - Length 170
d0 - Ø Broca 16
hnom - Min. anchor depth 110
h1 - Drill hole depth min. 104
tfix - Max. fixture thickness 48
Min. distance to edge “A” 126
SW - Installation key 24
Shear load non-cracked concrete 2237
Mº - M M16
df - Ø Element to fix 18
hmin - Min. substrate thickness 168
hef - Effective depth 84
Tins - Torque (Nm) 120
Min. distance from axis "B" 252
Tension load non-cracked concrete 1887
AH16220 M16 x 220 Ø16 512,003 25 50 8423533684998
L - Length 220
d0 - Ø Broca 16
hnom - Min. anchor depth 110
h1 - Drill hole depth min. 104
tfix - Max. fixture thickness 98
Min. distance to edge “A” 126
SW - Installation key 24
Shear load non-cracked concrete 2237
Mº - M M16
df - Ø Element to fix 18
hmin - Min. substrate thickness 168
hef - Effective depth 84
Tins - Torque (Nm) 120
Min. distance from axis "B" 252
Tension load non-cracked concrete 1887
AH16250 M16 x 250 Ø16 663,950 25 50 8423533685001
L - Length 250
d0 - Ø Broca 16
hnom - Min. anchor depth 110
h1 - Drill hole depth min. 104
tfix - Max. fixture thickness 128
Min. distance to edge “A” 126
SW - Installation key 24
Shear load non-cracked concrete 2237
Mº - M M16
df - Ø Element to fix 18
hmin - Min. substrate thickness 168
hef - Effective depth 84
Tins - Torque (Nm) 120
Min. distance from axis "B" 252
Tension load non-cracked concrete 1887
AH16280 M16 x 280 Ø16 722,767 25 50 8423533685018
L - Length 280
d0 - Ø Broca 16
hnom - Min. anchor depth 110
h1 - Drill hole depth min. 104
tfix - Max. fixture thickness 158
Min. distance to edge “A” 126
SW - Installation key 24
Shear load non-cracked concrete 2237
Mº - M M16
df - Ø Element to fix 18
hmin - Min. substrate thickness 168
hef - Effective depth 84
Tins - Torque (Nm) 120
Min. distance from axis "B" 252
Tension load non-cracked concrete 1887
AH20170 M20 x 170 Ø20 634,540 20 40 8423533575227
L - Length 170
d0 - Ø Broca 20
hnom - Min. anchor depth 135
h1 - Drill hole depth min. 125
tfix - Max. fixture thickness 23
Min. distance to edge “A” 155
SW - Installation key 30
Shear load non-cracked concrete 3279
Mº - M M20
df - Ø Element to fix 22
hmin - Min. substrate thickness 206
hef - Effective depth 103
Tins - Torque (Nm) 240
Min. distance from axis "B" 309
Tension load non-cracked concrete 2496
AH20220 M20 x 220 Ø20 790,093 20 40 8423533685025
L - Length 220
d0 - Ø Broca 20
hnom - Min. anchor depth 135
h1 - Drill hole depth min. 125
tfix - Max. fixture thickness 73
Min. distance to edge “A” 155
SW - Installation key 30
Shear load non-cracked concrete 3279
Mº - M M20
df - Ø Element to fix 22
hmin - Min. substrate thickness 206
hef - Effective depth 103
Tins - Torque (Nm) 240
Min. distance from axis "B" 309
Tension load non-cracked concrete 2496
AH20270 M20 x 270 Ø20 1.079,783 20 40 8423533685032
L - Length 270
d0 - Ø Broca 20
hnom - Min. anchor depth 135
h1 - Drill hole depth min. 125
tfix - Max. fixture thickness 123
Min. distance to edge “A” 155
SW - Installation key 30
Shear load non-cracked concrete 3279
Mº - M M20
df - Ø Element to fix 22
hmin - Min. substrate thickness 206
hef - Effective depth 103
Tins - Torque (Nm) 240
Min. distance from axis "B" 309
Tension load non-cracked concrete 2496
LSAH06060 M6 x 60 Ø6 14,877 30 6 8423533763198
L - Length 60
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 2
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 297
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 385
LSAH08060 M8 x 60 Ø8 12,211 20 6 8423533763204
L - Length 60
d0 - Ø Broca 8
hnom - Min. anchor depth 50
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 3
Min. distance to edge “A” 53
SW - Installation key 13
Shear load non-cracked concrete 494
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 35
Tins - Torque (Nm) 20
Min. distance from axis "B" 105
Tension load non-cracked concrete 485
LSAH08075 M8 x 75 Ø8 10,919 16 6 8423533763211
L - Length 75
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 5
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 542
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 676
LSAH08090 M8 x 90 Ø8 10,333 14 6 8423533763228
L - Length 90
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 20
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 542
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 676
LSAH10070 M10 x 70 Ø10 9,022 10 5 8423533763235
L - Length 70
d0 - Ø Broca 10
hnom - Min. anchor depth 60
h1 - Drill hole depth min. 54
tfix - Max. fixture thickness 3
Min. distance to edge “A” 63
SW - Installation key 17
Shear load non-cracked concrete 650
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 100
hef - Effective depth 42
Tins - Torque (Nm) 35
Min. distance from axis "B" 126
Tension load non-cracked concrete 650
LSAH10090 M10 x 90 Ø10 8,110 8 6 8423533763242
L - Length 90
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 10
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 856
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 922
LSAH10120 M10 x 120 Ø10 7,895 6 6 8423533763259
L - Length 120
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 40
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 856
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 922
LSAH12090 M12 x 90 Ø12 9,687 6 5 8423533763266
L - Length 90
d0 - Ø Broca 12
hnom - Min. anchor depth 70
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 13
Min. distance to edge “A” 75
SW - Installation key 19
Shear load non-cracked concrete 844
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 100
hef - Effective depth 50
Tins - Torque (Nm) 60
Min. distance from axis "B" 150
Tension load non-cracked concrete 844
LSAH12110 M12 x 110 Ø12 10,114 6 5 8423533763273
L - Length 110
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 18
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1200
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1251
LSAH16125 M16 x 125 Ø16 7,242 2 6 8423533763297
L - Length 125
d0 - Ø Broca 16
hnom - Min. anchor depth 110
h1 - Drill hole depth min. 104
tfix - Max. fixture thickness 3
Min. distance to edge “A” 126
SW - Installation key 24
Shear load non-cracked concrete 2237
Mº - M M16
df - Ø Element to fix 18
hmin - Min. substrate thickness 168
hef - Effective depth 84
Tins - Torque (Nm) 120
Min. distance from axis "B" 252
Tension load non-cracked concrete 1887
icono gps icono buscar