A PERFECT FIXING FOR YOUR BUSINESS
(+34) 941.272.131
MTH-A4 - Through bolt anchor for heavy loads in uncracked concrete.
MTH-A4 - Through bolt anchor for heavy loads in uncracked concrete.
MTH-A4 - Through bolt anchor for heavy loads in uncracked concrete.
Youtube 1 - MTH-A4 - Through bolt anchor for heavy loads in uncracked concrete.
MTH-A4 - Through bolt anchor for heavy loads in uncracked concrete.
MTH-A4 - Through bolt anchor for heavy loads in uncracked concrete.
Youtube 1 - MTH-A4 - Through bolt anchor for heavy loads in uncracked concrete.

Metal fixings - MTH-A4

MTH-A4

Through bolt anchor for heavy loads in uncracked concrete. Opt.7 ETA Assessed. A4 Stainless steel shaft. A4 Stainless steel clip.

Amplify information > CAD data

  • Fixing of shelves
  • Steel structures
  • Protections
  • Street furniture
  • Machinery
  • Wooden structures
  • Antennae
  • Balcony railings
  • Road railings
  • Wooden railings
  • Beach railings
  • Ceiling lights
  • False ceilings
  • False ceilings
  • Ceiling lights
  • False ceilings
  • Ceiling lights
  • False ceilings
  • Ceilings
  • Ceilings
  • Ceilings
  • Ceilings
  • Ceilings
  • Ceilings
MTH-A4 - Through bolt anchor for heavy loads in uncracked concrete.
Concrete

Concrete

Reinforced concrete

Reinforced concrete

Stone

Stone

Code Dimension €/100€/Box€/Bag Professional boxPieces/Window BoxPieces/LS bag MasterboxWindow boxes/Box CVBags/Box LS EAN technical info.
MIA406045 M6 x 45 Ø6 199,437 200 1.200 8423533579645
L - Length 45
d0 - Ø Broca 6
hnom - Min. anchor depth 40
h1 - Drill hole depth min. 35
tfix - Max. fixture thickness 1
Min. distance to edge “A” 40
SW - Installation key 10
Shear load non-cracked concrete 287
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 25
Tins - Torque (Nm) 7
Min. distance from axis "B" 75
Tension load non-cracked concrete 298
MIA406060 M6 x 60 Ø6 217,273 200 1.200 8423533579652
L - Length 60
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 2
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 287
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 438
MIA406080 M6 x 80 Ø6 231,407 200 1.200 8423533579669
L - Length 80
d0 - Ø Broca 6
hnom - Min. anchor depth 55
h1 - Drill hole depth min. 50
tfix - Max. fixture thickness 22
Min. distance to edge “A” 60
SW - Installation key 10
Shear load non-cracked concrete 287
Mº - M M6
df - Ø Element to fix 7
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 7
Min. distance from axis "B" 120
Tension load non-cracked concrete 438
MIA408050 M8 x 50 Ø8 240,410 100 800 8423533579676
L - Length 50
d0 - Ø Broca 8
hnom - Min. anchor depth 40
h1 - Drill hole depth min. 35
tfix - Max. fixture thickness 4
Min. distance to edge “A” 40
SW - Installation key 13
Shear load non-cracked concrete 263
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 23
Tins - Torque (Nm) 20
Min. distance from axis "B" 75
Tension load non-cracked concrete 219
MIA408075 M8 x 75 Ø8 255,300 100 600 8423533087713
L - Length 75
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 5
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 522
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 582
MIA408090 M8 x 90 Ø8 284,887 100 600 8423533579683
L - Length 90
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 20
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 522
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 582
MIA408115 M8 x 115 Ø8 374,257 100 400 8423533579690
L - Length 115
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 45
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 522
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 582
MIA410070 M10 x 70 Ø10 418,123 100 400 8423533579706
L - Length 70
d0 - Ø Broca 10
hnom - Min. anchor depth 60
h1 - Drill hole depth min. 54
tfix - Max. fixture thickness 3
Min. distance to edge “A” 60
SW - Installation key 17
Shear load non-cracked concrete 650
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 100
hef - Effective depth 42
Tins - Torque (Nm) 35
Min. distance from axis "B" 120
Tension load non-cracked concrete 485
MIA410090 M10 x 90 Ø10 473,920 100 400 8423533087706
L - Length 90
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 10
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 834
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 647
MIA410120 M10 x 120 Ø10 576,097 50 300 8423533579713
L - Length 120
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 40
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 834
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 647
MIA410150 M10 x 150 Ø10 817,017 50 200 8423533579720
L - Length 150
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 70
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 834
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 647
MIA412075 M12 x 75 Ø12 625,273 50 300 8423533579737
L - Length 75
d0 - Ø Broca 12
hnom - Min. anchor depth 60
h1 - Drill hole depth min. 55
tfix - Max. fixture thickness 5
Min. distance to edge “A” 65
SW - Installation key 19
Shear load non-cracked concrete 673
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 100
hef - Effective depth 43
Tins - Torque (Nm) 60
Min. distance from axis "B" 130
Tension load non-cracked concrete 561
MIA412090 M12 x 90 Ø12 629,693 50 200 8423533579744
L - Length 90
d0 - Ø Broca 12
hnom - Min. anchor depth 70
h1 - Drill hole depth min. 62
tfix - Max. fixture thickness 13
Min. distance to edge “A” 75
SW - Installation key 19
Shear load non-cracked concrete 844
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 100
hef - Effective depth 50
Tins - Torque (Nm) 60
Min. distance from axis "B" 90
Tension load non-cracked concrete 647
MIA412110 M12 x 110 Ø12 688,820 50 200 8423533087812
L - Length 110
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 18
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1207
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1011
MIA412140 M12 x 140 Ø12 825,997 50 200 8423533579751
L - Length 140
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 48
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1207
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1011
MIA416090 M16 x 90 Ø16 1.493,993 25 150 8423533579768
L - Length 90
d0 - Ø Broca 16
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 69
tfix - Max. fixture thickness 4
Min. distance to edge “A” 75
SW - Installation key 24
Shear load non-cracked concrete 819
Mº - M M16
df - Ø Element to fix 18
hmin - Min. substrate thickness 100
hef - Effective depth 49
Tins - Torque (Nm) 120
Min. distance from axis "B" 150
Tension load non-cracked concrete 683
MIA416145 M16 x 145 Ø16 1.845,033 25 100 8423533579775
L - Length 145
d0 - Ø Broca 16
hnom - Min. anchor depth 110
h1 - Drill hole depth min. 104
tfix - Max. fixture thickness 23
Min. distance to edge “A” 126
SW - Installation key 24
Shear load non-cracked concrete 2256
Mº - M M16
df - Ø Element to fix 18
hmin - Min. substrate thickness 168
hef - Effective depth 84
Tins - Torque (Nm) 120
Min. distance from axis "B" 252
Tension load non-cracked concrete 1416
MIA416170 M16 x 170 Ø16 2.130,590 25 75 8423533579782
L - Length 170
d0 - Ø Broca 16
hnom - Min. anchor depth 110
h1 - Drill hole depth min. 104
tfix - Max. fixture thickness 48
Min. distance to edge “A” 126
SW - Installation key 24
Shear load non-cracked concrete 2256
Mº - M M16
df - Ø Element to fix 18
hmin - Min. substrate thickness 168
hef - Effective depth 84
Tins - Torque (Nm) 120
Min. distance from axis "B" 252
Tension load non-cracked concrete 1416
MIA420120 M20 x 120 Ø20 2.476,680 20 40 8423533579799
L - Length 120
d0 - Ø Broca 20
hnom - Min. anchor depth 105
h1 - Drill hole depth min. 93
tfix - Max. fixture thickness 5
Min. distance to edge “A” 110
SW - Installation key 30
Shear load non-cracked concrete 2857
Mº - M M20
df - Ø Element to fix 22
hmin - Min. substrate thickness 145
hef - Effective depth 71
Tins - Torque (Nm) 240
Min. distance from axis "B" 225
Tension load non-cracked concrete 1190
MIA420170 M20 x 170 Ø20 3.385,527 20 40 8423533579805
L - Length 170
d0 - Ø Broca 20
hnom - Min. anchor depth 135
h1 - Drill hole depth min. 125
tfix - Max. fixture thickness 23
Min. distance to edge “A” 155
SW - Installation key 30
Shear load non-cracked concrete 3521
Mº - M M20
df - Ø Element to fix 22
hmin - Min. substrate thickness 206
hef - Effective depth 103
Tins - Torque (Nm) 240
Min. distance from axis "B" 309
Tension load non-cracked concrete 2023
MIA420220 M20 x 220 Ø20 4.214,650 20 40 8423533579812
L - Length 220
d0 - Ø Broca 20
hnom - Min. anchor depth 135
h1 - Drill hole depth min. 125
tfix - Max. fixture thickness 73
Min. distance to edge “A” 155
SW - Installation key 30
Shear load non-cracked concrete 3521
Mº - M M20
df - Ø Element to fix 22
hmin - Min. substrate thickness 206
hef - Effective depth 103
Tins - Torque (Nm) 240
Min. distance from axis "B" 309
Tension load non-cracked concrete 2023
VMIA408075 M8 x 75 Ø8 34,530 10 8 8423533753830
L - Length 75
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 5
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 522
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 582
VMIA410090 M10 x 90 Ø10 47,257 8 8 8423533753847
L - Length 90
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 10
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 834
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 647
VMIA412110 M12 x 110 Ø12 54,067 6 8 8423533753854
L - Length 110
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 18
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1207
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1011
LSMIA408075 M8 x 75 Ø8 37,379 12 7 8423533761958
L - Length 75
d0 - Ø Broca 8
hnom - Min. anchor depth 65
h1 - Drill hole depth min. 60
tfix - Max. fixture thickness 5
Min. distance to edge “A” 72
SW - Installation key 13
Shear load non-cracked concrete 522
Mº - M M8
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 20
Min. distance from axis "B" 144
Tension load non-cracked concrete 582
LSMIA410090 M10 x 90 Ø10 48,798 8 7 8423533761989
L - Length 90
d0 - Ø Broca 10
hnom - Min. anchor depth 75
h1 - Drill hole depth min. 67
tfix - Max. fixture thickness 10
Min. distance to edge “A” 83
SW - Installation key 17
Shear load non-cracked concrete 834
Mº - M M10
df - Ø Element to fix 12
hmin - Min. substrate thickness 110
hef - Effective depth 55
Tins - Torque (Nm) 35
Min. distance from axis "B" 165
Tension load non-cracked concrete 647
LSMIA412110 M12 x 110 Ø12 53,124 6 5 8423533762016
L - Length 110
d0 - Ø Broca 12
hnom - Min. anchor depth 85
h1 - Drill hole depth min. 77
tfix - Max. fixture thickness 18
Min. distance to edge “A” 98
SW - Installation key 19
Shear load non-cracked concrete 1207
Mº - M M12
df - Ø Element to fix 14
hmin - Min. substrate thickness 130
hef - Effective depth 65
Tins - Torque (Nm) 60
Min. distance from axis "B" 195
Tension load non-cracked concrete 1011
icono gps icono buscar

name

address

city (state)

postcode

telephone

email

web

Request more information