Chemical fixings - CA-QU

CA-QU

Epoxy resin, quartz and a phial of hardener. Opt.8 ETA Assessed. Epoxy resin, quartz and a phial of hardener. Option 8 ETA Assessed.

> CAD data

  • Air conditioning units
  • Balcony railings
  • Road railings
  • Concrete building under construction
  • Industrial shelving
  • Street lights
  • Presses
  • Overhead cranes
  • Overhead cranes
Installation - CA-QU - Epoxy resin, quartz and a phial of hardener. Opt.8 ETA Assessed.
Concrete

Concrete

Solid brick

Solid brick

Stone

Stone

Reinforced concrete

Reinforced concrete

Code Dimension €/100 Pcs. Box Pcs. Masterbox EAN technical info.
CAQU008 8 x 80 Ø10 207,147 10 500 8423533046505
L - Length 80
df - Ø Element to fix 9
hmin - Min. substrate thickness 110
hef - Effective depth 80
Tins - Torque (Nm) 10
Min. distance from axis "B" 240
Tension load non-cracked concrete 809
d0 - Ø Drill 10
Drill hole depth min. 80
Min. anchor depth 80
tfix - Max. fixture thickness 17
Min. distance to edge “A” 120
SW - Installation key 13
Shear load non-cracked concrete 524
CAQU010 10 x 90 Ø12 211,907 10 500 8423533046604
L - Length 90
df - Ø Element to fix 12
hmin - Min. substrate thickness 120
hef - Effective depth 90
Tins - Torque (Nm) 20
Min. distance from axis "B" 180
Tension load non-cracked concrete 1214
d0 - Ø Drill 12
Drill hole depth min. 90
Min. anchor depth 90
tfix - Max. fixture thickness 25
Min. distance to edge “A” 90
SW - Installation key 17
Shear load non-cracked concrete 815
CAQU012 12 x 110 Ø14 220,943 10 200 8423533046703
L - Length 110
df - Ø Element to fix 14
hmin - Min. substrate thickness 140
hef - Effective depth 110
Tins - Torque (Nm) 40
Min. distance from axis "B" 220
Tension load non-cracked concrete 1618
d0 - Ø Drill 14
Drill hole depth min. 110
Min. anchor depth 110
tfix - Max. fixture thickness 32
Min. distance to edge “A” 110
SW - Installation key 19
Shear load non-cracked concrete 1223
CAQU016 16 x 125 Ø18 245,643 10 200 8423533046802
L - Length 125
df - Ø Element to fix 18
hmin - Min. substrate thickness 160
hef - Effective depth 125
Tins - Torque (Nm) 80
Min. distance from axis "B" 250
Tension load non-cracked concrete 2023
d0 - Ø Drill 18
Drill hole depth min. 125
Min. anchor depth 125
tfix - Max. fixture thickness 44
Min. distance to edge “A” 125
SW - Installation key 24
Shear load non-cracked concrete 2272
CAQU020 20 x 170 Ø25 499,807 6 60 8423533046901
L - Length 170
df - Ø Element to fix 22
hmin - Min. substrate thickness 220
hef - Effective depth 170
Tins - Torque (Nm) 120
Min. distance from axis "B" 340
Tension load non-cracked concrete 3034
d0 - Ø Drill 25
Drill hole depth min. 170
Min. anchor depth 170
tfix - Max. fixture thickness 66
Min. distance to edge “A” 170
SW - Installation key 30
Shear load non-cracked concrete 3553
CAQU024 24 x 210 Ø28 585,190 6 60 8423533047007
L - Length 210
df - Ø Element to fix 26
hmin - Min. substrate thickness 260
hef - Effective depth 210
Tins - Torque (Nm) 180
Min. distance from axis "B" 420
Tension load non-cracked concrete 3641
d0 - Ø Drill 28
Drill hole depth min. 210
Min. anchor depth 210
tfix - Max. fixture thickness 62
Min. distance to edge “A” 210
SW - Installation key 36
Shear load non-cracked concrete 5126
CAQU030 30 x 280 Ø35 1.043,510 6 30 8423533022455
L - Length 280
df - Ø Element to fix 33
hmin - Min. substrate thickness 360
hef - Effective depth 280
Tins - Torque (Nm) 300
Min. distance from axis "B" 560
Tension load non-cracked concrete 5461
d0 - Ø Drill 35
Drill hole depth min. 280
Min. anchor depth 280
tfix - Max. fixture thickness 22
Min. distance to edge “A” 280
SW - Installation key 46
Shear load non-cracked concrete 8496