A PERFECT FIXING FOR YOUR BUSINESS
(+34) 941.272.131
THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.
THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.
THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.
THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.
THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.
Youtube 1 - THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.
THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.
THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.
THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.
THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.
Youtube 1 - THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.

Metal fixings - THA

THA

Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed. Opt.1 ETA Assessed. Countersunk head.

Amplify information > CAD data

Anclaje metálico para hormigón con cabeza avellanada. Indicado para aplicaciones en hormigón fisurado y no fisurado. Está fabricado en acero al carbono estampado de alta resistencia, con un recubrimiento ATLANTIS C3-H que le confiere una mayor protección contra la corrosión en atmósferas de categoría C3, acorde a la norma ISO 9223. Este tipo de anclaje funciona por interferencia mecánica entre la rosca y el material base, lo que genera una baja carga sobre el hormigón, permitiendo una distancia mínima entre los anclajes y el borde del elemento de hormigón. Además, se trata de un tipo de anclaje desmontable, perfecto para aplicaciones temporales o que deban ajustarse, como barandillas, estructuras de acero, canales, maquinaria, calderas, señales o asientos, entre otras. Cuentan con un cuidado diseño que incluye una rosca doble patentada, diseñada para incrustarse profundamente en el hormigón y garantizar las máximas cargas. Además, su punta está templada para garantizar una mayor dureza, durabilidad y facilidad durante la instalación. Para garantizar su seguridad, estos tornillos para hormigón han sido homologados acorde a los más altos estándares de calidad según las normas ETA 20/0046 y ETA 20/0494. Además cuentan con homologación de resistencia a fuego R30-R120 en hormigón y homologación sísmica C1&C2. INDEX A PERFECT FIXING dispone de una amplia gama de medidas de esta fijación, desde Ø5 x 40 mm hasta Ø10 x 120 mm. Además, también dispone de 9 modelos de cabezas diferentes.
  • Structural applications
  • Temporary awnings or signage
  • Stadium seating
  • Wood to concrete structures
  • Railings and fencing
  • Shelving and racks
  • Structural beams and pillars
THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.
Installation - THA - Concrete screw anchor with ATLANTIS C3-H coating. Opt.1 ETA Assessed.
Concrete

Concrete

Cracked concrete

Cracked concrete

Reinforced concrete

Reinforced concrete

Hollow-core slab

Hollow-core slab

Stone

Stone

Code Dimension €/100 Pcs. Box Pcs. Masterbox EAN technical info.
THA05040 Ø5 x 40 54,380 100 2.400 8423533844859
L - Length 40
Mº - M Ø5
df - Ø Element to fix 8
hmin - Min. substrate thickness 80
tfix - Max. fixture thickness 5
Min. distance to edge “A” 40
SW - Installation key TX25
Shear load non-cracked concrete 326
Shear load cracked concrete 228
dk - Head Ø 10.4
d0 - Ø Drill 5
Drill hole depth min. 45
Min. anchor depth 35
Tins - Torque (Nm) 8
Min. distance from axis "B" 80
Tension load non-cracked concrete 326
Tension load cracked concrete 228
THA05060 Ø5 x 60 64,053 100 1.200 8423533844866
L - Length 60
Mº - M Ø5
df - Ø Element to fix 8
hmin - Min. substrate thickness 80
tfix - Max. fixture thickness 15
Min. distance to edge “A” 53
SW - Installation key TX25
Shear load non-cracked concrete 398
Shear load cracked concrete 346
dk - Head Ø 10.4
d0 - Ø Drill 5
Drill hole depth min. 55
Min. anchor depth 45
Tins - Torque (Nm) 8
Min. distance from axis "B" 105
Tension load non-cracked concrete 494
Tension load cracked concrete 346
THA05080 Ø5 x 80 81,180 50 800 8423533844873
L - Length 80
Mº - M Ø5
df - Ø Element to fix 8
hmin - Min. substrate thickness 80
tfix - Max. fixture thickness 35
Min. distance to edge “A” 53
SW - Installation key TX25
Shear load non-cracked concrete 398
Shear load cracked concrete 346
dk - Head Ø 10.4
d0 - Ø Drill 5
Drill hole depth min. 55
Min. anchor depth 45
Tins - Torque (Nm) 8
Min. distance from axis "B" 105
Tension load non-cracked concrete 494
Tension load cracked concrete 346
THA05100 Ø5 x 100 91,513 50 800 8423533844880
L - Length 100
Mº - M Ø5
df - Ø Element to fix 8
hmin - Min. substrate thickness 80
tfix - Max. fixture thickness 55
Min. distance to edge “A” 53
SW - Installation key TX25
Shear load non-cracked concrete 398
Shear load cracked concrete 346
dk - Head Ø 10.4
d0 - Ø Drill 5
Drill hole depth min. 55
Min. anchor depth 45
Tins - Torque (Nm) 8
Min. distance from axis "B" 105
Tension load non-cracked concrete 494
Tension load cracked concrete 346
THA06045 Ø6 x 45 75,860 100 1.600 8423533844897
L - Length 45
Mº - M Ø6
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 10
Min. distance to edge “A” 39
SW - Installation key TX30
Shear load non-cracked concrete 608
Shear load cracked concrete 454
dk - Head Ø 12.4
d0 - Ø Drill 6
Drill hole depth min. 45
Min. anchor depth 35
Tins - Torque (Nm) 10
Min. distance from axis "B" 78
Tension load non-cracked concrete 202
Tension load cracked concrete 185
THA06050 Ø6 x 50 79,100 100 1.200 8423533844903
L - Length 50
Mº - M Ø6
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 15
Min. distance to edge “A” 39
SW - Installation key TX30
Shear load non-cracked concrete 608
Shear load cracked concrete 454
dk - Head Ø 12.4
d0 - Ø Drill 6
Drill hole depth min. 45
Min. anchor depth 35
Tins - Torque (Nm) 10
Min. distance from axis "B" 78
Tension load non-cracked concrete 202
Tension load cracked concrete 185
THA06060 Ø6 x 60 93,003 100 1.200 8423533844910
L - Length 60
Mº - M Ø6
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 5
Min. distance to edge “A” 65
SW - Installation key TX30
Shear load non-cracked concrete 608
Shear load cracked concrete 542
dk - Head Ø 12.4
d0 - Ø Drill 6
Drill hole depth min. 65
Min. anchor depth 55
Tins - Torque (Nm) 10
Min. distance from axis "B" 129
Tension load non-cracked concrete 673
Tension load cracked concrete 471
THA06080 Ø6 x 80 112,020 100 600 8423533844927
L - Length 80
Mº - M Ø6
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 25
Min. distance to edge “A” 65
SW - Installation key TX30
Shear load non-cracked concrete 608
Shear load cracked concrete 542
dk - Head Ø 12.4
d0 - Ø Drill 6
Drill hole depth min. 65
Min. anchor depth 55
Tins - Torque (Nm) 10
Min. distance from axis "B" 129
Tension load non-cracked concrete 673
Tension load cracked concrete 471
THA06100 Ø6 x 100 0,000 100 600 8423533907912
L - Length 100
Mº - M Ø6
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 45
Min. distance to edge “A” 65
SW - Installation key TX30
Shear load non-cracked concrete 608
Shear load cracked concrete 542
dk - Head Ø 12.4
d0 - Ø Drill 6
Drill hole depth min. 65
Min. anchor depth 55
Tins - Torque (Nm) 10
Min. distance from axis "B" 129
Tension load non-cracked concrete 673
Tension load cracked concrete 471
THA06120 Ø6 x 120 125,833 100 400 8423533844934
L - Length 120
Mº - M Ø6
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 65
Min. distance to edge “A” 65
SW - Installation key TX30
Shear load non-cracked concrete 608
Shear load cracked concrete 542
dk - Head Ø 12.4
d0 - Ø Drill 6
Drill hole depth min. 65
Min. anchor depth 55
Tins - Torque (Nm) 10
Min. distance from axis "B" 129
Tension load non-cracked concrete 673
Tension load cracked concrete 471
THA06140 Ø6 x 140 161,323 100 600 8423533844941
L - Length 140
Mº - M Ø6
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 85
Min. distance to edge “A” 65
SW - Installation key TX30
Shear load non-cracked concrete 608
Shear load cracked concrete 542
dk - Head Ø 12.4
d0 - Ø Drill 6
Drill hole depth min. 65
Min. anchor depth 55
Tins - Torque (Nm) 10
Min. distance from axis "B" 129
Tension load non-cracked concrete 673
Tension load cracked concrete 471
THA08060 Ø8 x 60 153,210 50 200 8423533844958
L - Length 60
Mº - M Ø8
df - Ø Element to fix 12
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 10
Min. distance to edge “A” 57
SW - Installation key TX45
Shear load non-cracked concrete 950
Shear load cracked concrete 691
dk - Head Ø 18
d0 - Ø Drill 8
Drill hole depth min. 60
Min. anchor depth 50
Tins - Torque (Nm) 20
Min. distance from axis "B" 113
Tension load non-cracked concrete 457
Tension load cracked concrete 320
THA08080 Ø8 x 80 186,177 25 400 8423533844965
L - Length 80
Mº - M Ø8
df - Ø Element to fix 12
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 15
Min. distance to edge “A” 76
SW - Installation key TX45
Shear load non-cracked concrete 950
Shear load cracked concrete 762
dk - Head Ø 18
d0 - Ø Drill 8
Drill hole depth min. 75
Min. anchor depth 65
Tins - Torque (Nm) 20
Min. distance from axis "B" 152
Tension load non-cracked concrete 857
Tension load cracked concrete 600
THA08100 Ø8 x 100 223,920 25 400 8423533844972
L - Length 100
Mº - M Ø8
df - Ø Element to fix 12
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 35
Min. distance to edge “A” 76
SW - Installation key TX45
Shear load non-cracked concrete 950
Shear load cracked concrete 762
dk - Head Ø 18
d0 - Ø Drill 8
Drill hole depth min. 75
Min. anchor depth 65
Tins - Torque (Nm) 20
Min. distance from axis "B" 152
Tension load non-cracked concrete 857
Tension load cracked concrete 600
THA08120 Ø8 x 120 251,283 25 400 8423533844989
L - Length 120
Mº - M Ø8
df - Ø Element to fix 12
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 55
Min. distance to edge “A” 76
SW - Installation key TX45
Shear load non-cracked concrete 950
Shear load cracked concrete 762
dk - Head Ø 18
d0 - Ø Drill 8
Drill hole depth min. 75
Min. anchor depth 65
Tins - Torque (Nm) 20
Min. distance from axis "B" 152
Tension load non-cracked concrete 857
Tension load cracked concrete 600
THA10100 Ø10 x 100 339,207 25 300 8423533844996
L - Length 100
Mº - M Ø10
df - Ø Element to fix 14
hmin - Min. substrate thickness 135
tfix - Max. fixture thickness 15
Min. distance to edge “A” 101
SW - Installation key TX50
Shear load non-cracked concrete 1330
Shear load cracked concrete 762
dk - Head Ø 21
d0 - Ø Drill 10
Drill hole depth min. 95
Min. anchor depth 85
Tins - Torque (Nm) 30
Min. distance from axis "B" 201
Tension load non-cracked concrete 1310
Tension load cracked concrete 600
THA10120 Ø10 x 120 393,763 25 200 8423533845009
L - Length 120
Mº - M Ø10
df - Ø Element to fix 14
hmin - Min. substrate thickness 135
tfix - Max. fixture thickness 35
Min. distance to edge “A” 101
SW - Installation key TX50
Shear load non-cracked concrete 1330
Shear load cracked concrete 762
dk - Head Ø 21
d0 - Ø Drill 10
Drill hole depth min. 95
Min. anchor depth 85
Tins - Torque (Nm) 30
Min. distance from axis "B" 201
Tension load non-cracked concrete 1310
Tension load cracked concrete 600
icono gps icono buscar

name

address

city (state)

postcode

telephone

email

web

Request more information

Cookies Policy

We use our own cookies, as well as third party cookies, to analyse website use and consumption parameters so we can improve our services. To change cookie settings or obtain further information, click here.