A PERFECT FIXING FOR YOUR BUSINESS
(+34) 941.272.131
SL-PC - Heavy duty anchor for high perfomance in concrete.
SL-PC - Heavy duty anchor for high perfomance in concrete.
Youtube - SL-PC - Heavy duty anchor for high perfomance in concrete.
SL-PC - Heavy duty anchor for high perfomance in concrete.
Youtube - SL-PC - Heavy duty anchor for high perfomance in concrete.

Metal fixings - SL-PC

SL-PC

Heavy duty anchor for high perfomance in concrete. Opt.1 ETA Assessed. Countersunk head.

> CAD data

  • Scaffolding
  • Antennae
  • Road guardrails
  • Concrete building under construction
  • Site hoist
  • Industrial shelving
  • Street lamp
  • Road lamp

Installation instructions - SL-PC - Heavy duty anchor for high perfomance in concrete.

Concrete

Concrete

Cracked concrete

Cracked concrete

Reinforced concrete

Reinforced concrete

Stone

Stone

Code Dimension €/100 UDS. Box UDS. Master EAN technical info.
SLPC10070 M6 x 70 Ø10 428,500 50 600 8423533828033
L - Length 70
d0 - Ø Broca 10
h1 - Drill hole depth min. 70
hnom - Min. anchor depth 59
tfix - Max. fixture thickness 10
Min. distance to edge “A” 75
SW - Installation key 4
Shear load non-cracked concrete 844
Shear load cracked concrete 591
Mº - M M6
df - Ø Element to fix 12
hmin - Min. substrate thickness 100
hef - Effective depth 50
Tins - Torque (Nm) 15
Min. distance from axis "B" 150
Tension load non-cracked concrete 782
Tension load cracked concrete 591
SLPC10080 M6 x 80 Ø10 451,737 50 600 8423533828040
L - Length 80
d0 - Ø Broca 10
h1 - Drill hole depth min. 70
hnom - Min. anchor depth 59
tfix - Max. fixture thickness 20
Min. distance to edge “A” 75
SW - Installation key 4
Shear load non-cracked concrete 844
Shear load cracked concrete 591
Mº - M M6
df - Ø Element to fix 12
hmin - Min. substrate thickness 100
hef - Effective depth 50
Tins - Torque (Nm) 15
Min. distance from axis "B" 150
Tension load non-cracked concrete 782
Tension load cracked concrete 591
SLPC10100 M6 x 100 Ø10 493,760 50 300 8423533828422
L - Length 100
d0 - Ø Broca 10
h1 - Drill hole depth min. 70
hnom - Min. anchor depth 59
tfix - Max. fixture thickness 40
Min. distance to edge “A” 75
SW - Installation key 4
Shear load non-cracked concrete 844
Shear load cracked concrete 591
Mº - M M6
df - Ø Element to fix 12
hmin - Min. substrate thickness 100
hef - Effective depth 50
Tins - Torque (Nm) 15
Min. distance from axis "B" 150
Tension load non-cracked concrete 782
Tension load cracked concrete 591
SLPC12100 M8 x 100 Ø12 587,177 50 200 8423533828057
L - Length 100
d0 - Ø Broca 12
h1 - Drill hole depth min. 85
hnom - Min. anchor depth 72
tfix - Max. fixture thickness 25
Min. distance to edge “A” 90
SW - Installation key 5
Shear load non-cracked concrete 1922
Shear load cracked concrete 1554
Mº - M M8
df - Ø Element to fix 14
hmin - Min. substrate thickness 120
hef - Effective depth 60
Tins - Torque (Nm) 30
Min. distance from axis "B" 180
Tension load non-cracked concrete 1110
Tension load cracked concrete 777
SLPC16100 M10 x 100 Ø16 847,893 25 150 8423533828064
L - Length 100
d0 - Ø Broca 16
h1 - Drill hole depth min. 95
hnom - Min. anchor depth 83
tfix - Max. fixture thickness 15
Min. distance to edge “A” 105
SW - Installation key 6
Shear load non-cracked concrete 2797
Shear load cracked concrete 1958
Mº - M M10
df - Ø Element to fix 18
hmin - Min. substrate thickness 140
hef - Effective depth 70
Tins - Torque (Nm) 50
Min. distance from axis "B" 210
Tension load non-cracked concrete 1399
Tension load cracked concrete 979
SLPC16120 M10 x 120 Ø16 920,677 25 100 8423533828071
L - Length 120
d0 - Ø Broca 16
h1 - Drill hole depth min. 95
hnom - Min. anchor depth 83
tfix - Max. fixture thickness 35
Min. distance to edge “A” 105
SW - Installation key 6
Shear load non-cracked concrete 2797
Shear load cracked concrete 1958
Mº - M M10
df - Ø Element to fix 18
hmin - Min. substrate thickness 140
hef - Effective depth 70
Tins - Torque (Nm) 50
Min. distance from axis "B" 210
Tension load non-cracked concrete 1399
Tension load cracked concrete 979
SLPC18120 M12 x 120 Ø18 1.140,630 20 80 8423533828088
L - Length 120
d0 - Ø Broca 18
h1 - Drill hole depth min. 110
hnom - Min. anchor depth 97
tfix - Max. fixture thickness 20
Min. distance to edge “A” 130
SW - Installation key 8
Shear load non-cracked concrete 3743
Shear load cracked concrete 2620
Mº - M M12
df - Ø Element to fix 20
hmin - Min. substrate thickness 170
hef - Effective depth 85
Tins - Torque (Nm) 80
Min. distance from axis "B" 255
Tension load non-cracked concrete 1871
Tension load cracked concrete 1310