TNUXE08060
8 x 60 Ø8
58,950
50
600
8423533695130
L -
Length
60
d0 - Ø Broca
8
hnom - Min. anchor depth
70
h1 - Drill hole depth min.
50
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
50
Min. distance to edge “A”
60
SW - Installation key
SW10/TX30
Shear load non-cracked concrete
263
TNUXE08080
8 x 80 Ø8
67,180
50
600
8423533695147
L -
Length
80
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
SW10/TX30
Shear load non-cracked concrete
263
TNUXE08100
8 x 100 Ø8
84,863
50
300
8423533695154
L -
Length
100
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
SW10/TX30
Shear load non-cracked concrete
263
TNUXE08120
8 x 120 Ø8
99,383
50
300
8423533695161
L -
Length
120
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
50
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
SW10/TX30
Shear load non-cracked concrete
263
TNUXE10060
10 x 60 Ø10
86,830
50
300
8423533695178
L -
Length
60
d0 - Ø Broca
10
hnom - Min. anchor depth
70
h1 - Drill hole depth min.
50
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
50
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
TNUXE10080
10 x 80 Ø10
102,387
50
300
8423533695314
L -
Length
80
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
TNUXE10100
10 x 100 Ø10
118,727
50
300
8423533695321
L -
Length
100
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
TNUXE10120
10 x 120 Ø10
158,407
50
300
8423533695338
L -
Length
120
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
50
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
TNUXE10140
10 x 140 Ø10
202,157
50
200
8423533695345
L -
Length
140
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
70
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
TNUXE10160
10 x 160 Ø10
202,630
50
150
8423533695352
L -
Length
160
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
90
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
TNUXE10180
10 x 180 Ø10
244,287
50
150
8423533695369
L -
Length
180
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
110
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
TNUXE10200
10 x 200 Ø10
322,963
50
150
8423533695376
L -
Length
200
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
130
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
TNUXE10230
10 x 230 Ø10
393,557
50
100
8423533695383
L -
Length
230
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
160
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
BZTNXE08080
8 x 80 Ø8
3,071
2
15
8423533422231
L -
Length
80
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
SW10/TX30
Shear load non-cracked concrete
263
BZTNXE08100
8 x 100 Ø8
3,071
2
15
8423533422248
L -
Length
100
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
SW10/TX30
Shear load non-cracked concrete
263
BZTNXE08120
8 x 120 Ø8
3,071
2
15
8423533422255
L -
Length
120
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
50
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
SW10/TX30
Shear load non-cracked concrete
263
BZTNXE10080
10 x 80 Ø10
3,071
2
15
8423533422262
L -
Length
80
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
BZTNXE10100
10 x 100 Ø10
3,233
2
15
8423533422279
L -
Length
100
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
BZTNXE10120
10 x 120 Ø10
3,233
2
15
8423533422286
L -
Length
120
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
50
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
VTNUXE08080
8 x 80 Ø8
6,837
8
8
8423533755292
L -
Length
80
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
SW10/TX30
Shear load non-cracked concrete
263
VTNUXE08100
8 x 100 Ø8
8,633
8
8
8423533755308
L -
Length
100
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
SW10/TX30
Shear load non-cracked concrete
263
VTNUXE10080
10 x 80 Ø10
10,415
8
8
8423533755315
L -
Length
80
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
VTNUXE10100
10 x 100 Ø10
12,075
8
8
8423533755322
L -
Length
100
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
LSTNXE08080
8 x 80 Ø8
7,467
10
8
8423533763853
L -
Length
80
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
SW10/TX30
Shear load non-cracked concrete
263
LSTNXE08100
8 x 100 Ø8
9,434
10
8
8423533771643
L -
Length
100
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
SW10/TX30
Shear load non-cracked concrete
263
LSTNXE08120
8 x 120 Ø8
9,904
8
8
8423533771650
L -
Length
120
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
50
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
SW10/TX30
Shear load non-cracked concrete
263
LSTNXE10080
10 x 80 Ø10
6,832
6
6
8423533771667
L -
Length
80
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364
LSTNXE10100
10 x 100 Ø10
7,921
6
6
8423533763846
L -
Length
100
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
SW13/TX40
Shear load non-cracked concrete
364