A PERFECT FIXING FOR YOUR BUSINESS
(+34) 941.272.131
CH-ES - Anti-spin sleeve anchor for medium loads.
CH-ES - Anti-spin sleeve anchor for medium loads.
CH-ES - Anti-spin sleeve anchor for medium loads.
CH-ES - Anti-spin sleeve anchor for medium loads.
CH-ES - Anti-spin sleeve anchor for medium loads.
CH-ES - Anti-spin sleeve anchor for medium loads.
Youtube 1 - CH-ES - Anti-spin sleeve anchor for medium loads.
CH-ES - Anti-spin sleeve anchor for medium loads.
CH-ES - Anti-spin sleeve anchor for medium loads.
CH-ES - Anti-spin sleeve anchor for medium loads.
CH-ES - Anti-spin sleeve anchor for medium loads.
CH-ES - Anti-spin sleeve anchor for medium loads.
Youtube 1 - CH-ES - Anti-spin sleeve anchor for medium loads.

Metal fixings - CH-ES

CH-ES

Anti-spin sleeve anchor for medium loads. Projecting bolt.

Amplify information > CAD data

  • Air conditioning units
  • Aerials
  • Street furniture
  • Railings
  • Balcony railings
  • Road railings
  • Wooden railings
  • Marquees
  • Tents
  • Signs
  • Banners
CH-ES - Anti-spin sleeve anchor for medium loads.
CH-ES - Anti-spin sleeve anchor for medium loads.
CH-ES - Anti-spin sleeve anchor for medium loads.
Installation - CH-ES - Anti-spin sleeve anchor for medium loads.
Reinforced concrete

Reinforced concrete

Concrete

Concrete

Stone

Stone

Solid brick

Solid brick

Code Dimension €/100 Pcs. Box Pcs. Masterbox EAN technical info.
ACHE08C M6 x 45 Ø8 55,217 200 1.200 8423533584090
L - Length 45
d0 - Ø Drill 8
Drill hole depth min. 45
Min. anchor depth 39
tfix - Max. fixture thickness 5
Min. distance to edge “A” 41
SW - Installation key 10
Shear load non-cracked concrete 211
Mº - M M6
df - Ø Element to fix 9
hmin - Min. substrate thickness 100
hef - Effective depth 30
Tins - Torque (Nm) 10
Min. distance from axis "B" 41
Tension load non-cracked concrete 267
ACHE09C M6 x 45 Ø9 57,150 200 800 8423533584106
L - Length 45
d0 - Ø Drill 9
Drill hole depth min. 45
Min. anchor depth 39
tfix - Max. fixture thickness 5
Min. distance to edge “A” 41
SW - Installation key 10
Shear load non-cracked concrete 211
Mº - M M6
df - Ø Element to fix 10
hmin - Min. substrate thickness 100
hef - Effective depth 30
Tins - Torque (Nm) 10
Min. distance from axis "B" 41
Tension load non-cracked concrete 267
ACHE10C M8 x 60 Ø10 81,670 100 600 8423533584113
L - Length 60
d0 - Ø Drill 10
Drill hole depth min. 60
Min. anchor depth 51
tfix - Max. fixture thickness 5
Min. distance to edge “A” 54
SW - Installation key 13
Shear load non-cracked concrete 384
Mº - M M8
df - Ø Element to fix 12
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 20
Min. distance from axis "B" 54
Tension load non-cracked concrete 485
ACHE11C M8 x 60 Ø11 90,063 100 600 8423533584120
L - Length 60
d0 - Ø Drill 11
Drill hole depth min. 60
Min. anchor depth 51
tfix - Max. fixture thickness 5
Min. distance to edge “A” 54
SW - Installation key 13
Shear load non-cracked concrete 384
Mº - M M8
df - Ø Element to fix 13
hmin - Min. substrate thickness 100
hef - Effective depth 40
Tins - Torque (Nm) 20
Min. distance from axis "B" 54
Tension load non-cracked concrete 485
ACHE10L M8 x 80 Ø10 95,103 100 400 8423533584137
L - Length 80
d0 - Ø Drill 10
Drill hole depth min. 60
Min. anchor depth 51
tfix - Max. fixture thickness 27
Min. distance to edge “A” 54
SW - Installation key 13
Shear load non-cracked concrete 384
Mº - M M8
df - Ø Element to fix 12
hmin - Min. substrate thickness 105
hef - Effective depth 40
Tins - Torque (Nm) 20
Min. distance from axis "B" 54
Tension load non-cracked concrete 485
ACHE11L M8 x 80 Ø11 99,533 100 400 8423533584144
L - Length 80
d0 - Ø Drill 11
Drill hole depth min. 60
Min. anchor depth 51
tfix - Max. fixture thickness 27
Min. distance to edge “A” 54
SW - Installation key 13
Shear load non-cracked concrete 384
Mº - M M8
df - Ø Element to fix 13
hmin - Min. substrate thickness 105
hef - Effective depth 40
Tins - Torque (Nm) 20
Min. distance from axis "B" 54
Tension load non-cracked concrete 485
ACHE12C M10 x 70 Ø12 115,730 100 200 8423533584168
L - Length 70
d0 - Ø Drill 12
Drill hole depth min. 75
Min. anchor depth 65
tfix - Max. fixture thickness 5
Min. distance to edge “A” 65
SW - Installation key 17
Shear load non-cracked concrete 608
Mº - M M10
df - Ø Element to fix 14
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 35
Min. distance from axis "B" 65
Tension load non-cracked concrete 662
ACHE14C M10 x 70 Ø14 127,273 100 200 8423533584175
L - Length 70
d0 - Ø Drill 14
Drill hole depth min. 75
Min. anchor depth 65
tfix - Max. fixture thickness 5
Min. distance to edge “A” 65
SW - Installation key 17
Shear load non-cracked concrete 608
Mº - M M10
df - Ø Element to fix 16
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 35
Min. distance from axis "B" 65
Tension load non-cracked concrete 662
ACHE12L M10 x 100 Ø12 151,463 50 200 8423533584182
L - Length 100
d0 - Ø Drill 12
Drill hole depth min. 75
Min. anchor depth 65
tfix - Max. fixture thickness 32
Min. distance to edge “A” 65
SW - Installation key 17
Shear load non-cracked concrete 608
Mº - M M10
df - Ø Element to fix 14
hmin - Min. substrate thickness 110
hef - Effective depth 48
Tins - Torque (Nm) 35
Min. distance from axis "B" 65
Tension load non-cracked concrete 662
ACHE14L M10 x 100 Ø14 170,913 50 200 8423533584199
L - Length 100
d0 - Ø Drill 14
Drill hole depth min. 75
Min. anchor depth 65
tfix - Max. fixture thickness 32
Min. distance to edge “A” 65
SW - Installation key 17
Shear load non-cracked concrete 608
Mº - M M10
df - Ø Element to fix 16
hmin - Min. substrate thickness 100
hef - Effective depth 48
Tins - Torque (Nm) 35
Min. distance from axis "B" 65
Tension load non-cracked concrete 662