A PERFECT FIXING FOR YOUR BUSINESS
(+34) 941.272.131
AIS-M - Metallic fixing plug for insulation panels.
AIS-M - Metallic fixing plug for insulation panels.
AIS-M - Metallic fixing plug for insulation panels.
AIS-M - Metallic fixing plug for insulation panels.
Youtube 1 - AIS-M - Metallic fixing plug for insulation panels.
AIS-M - Metallic fixing plug for insulation panels.
AIS-M - Metallic fixing plug for insulation panels.
AIS-M - Metallic fixing plug for insulation panels.
Youtube 1 - AIS-M - Metallic fixing plug for insulation panels.

Fixings and accessories for thermal insulation systems (ETICS) - AIS-M

AIS-M

Metallic fixing plug for insulation panels.

Amplify information

  • Fixing of external thermal insulation panels of different types (mineral wool
  • Polystyrenes
  • Glass wool
  • Rock wool
  • Cork
  • Cellulose panels
  • Etc.)
  • Façade renovation (SATE)
  • Insulation systems for all types of façades
Installation - AIS-M - Metallic fixing plug for insulation panels.
Concrete

Concrete

Code Dimension €/100 Pcs. Box Pcs. Masterbox EAN technical info.
AISM08090 Ø8 x 90 30,323 250 8423533867896
L - Length 90
d0 - Ø Drill 8
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 50
Min. distance from axis "B" 100
Tension load cracked concrete 10
Mº - M 8
Drill hole depth min. 50
Min. anchor depth 40
Min. distance to edge “A” 100
Tension load non-cracked concrete 10
AISM08110 Ø8 x 110 35,650 250 8423533867902
L - Length 110
d0 - Ø Drill 8
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 70
Min. distance from axis "B" 100
Tension load cracked concrete 10
Mº - M 8
Drill hole depth min. 50
Min. anchor depth 40
Min. distance to edge “A” 100
Tension load non-cracked concrete 10
AISM08120 Ø8 x 120 36,823 250 8423533867919
L - Length 120
d0 - Ø Drill 8
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 80
Min. distance from axis "B" 100
Tension load cracked concrete 10
Mº - M 8
Drill hole depth min. 50
Min. anchor depth 40
Min. distance to edge “A” 100
Tension load non-cracked concrete 10
AISM08140 Ø8 x 140 41,333 250 8423533867926
L - Length 140
d0 - Ø Drill 8
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 100
Min. distance from axis "B" 100
Tension load cracked concrete 10
Mº - M 8
Drill hole depth min. 50
Min. anchor depth 40
Min. distance to edge “A” 100
Tension load non-cracked concrete 10
AISM08170 Ø8 x 170 49,550 250 8423533867940
L - Length 170
d0 - Ø Drill 8
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 130
Min. distance from axis "B" 100
Tension load cracked concrete 10
Mº - M 8
Drill hole depth min. 50
Min. anchor depth 40
Min. distance to edge “A” 100
Tension load non-cracked concrete 10
AISM08200 Ø8 x 200 63,990 250 8423533867957
L - Length 200
d0 - Ø Drill 8
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 160
Min. distance from axis "B" 100
Tension load cracked concrete 10
Mº - M 8
Drill hole depth min. 50
Min. anchor depth 40
Min. distance to edge “A” 100
Tension load non-cracked concrete 10
AISM08250 Ø8 x 250 75,087 250 8423533867964
L - Length 250
d0 - Ø Drill 8
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 210
Min. distance from axis "B" 100
Tension load cracked concrete 10
Mº - M 8
Drill hole depth min. 50
Min. anchor depth 40
Min. distance to edge “A” 100
Tension load non-cracked concrete 10
AISM08300 Ø8 x 300 123,100 250 8423533867971
L - Length 300
d0 - Ø Drill 8
hmin - Min. substrate thickness 100
tfix - Max. fixture thickness 260
Min. distance from axis "B" 100
Tension load cracked concrete 10
Mº - M 8
Drill hole depth min. 50
Min. anchor depth 40
Min. distance to edge “A” 100
Tension load non-cracked concrete 10
icono gps icono buscar

name

address

city (state)

postcode

telephone

email

web

Request more information

Cookies Policy

We use our own cookies, as well as third party cookies, to analyse website use and consumption parameters so we can improve our services. To change cookie settings or obtain further information, click here.