TNUXA08060
8 x 60 Ø8
51,260
50
600
8423533695185
L -
Length
60
d0 - Ø Broca
8
hnom - Min. anchor depth
70
h1 - Drill hole depth min.
50
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
50
Min. distance to edge “A”
60
SW - Installation key
TX30
Shear load non-cracked concrete
263
TNUXA08080
8 x 80 Ø8
56,110
50
600
8423533695192
L -
Length
80
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
TX30
Shear load non-cracked concrete
263
TNUXA08100
8 x 100 Ø8
70,137
50
600
8423533695208
L -
Length
100
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
TX30
Shear load non-cracked concrete
263
TNUXA08120
8 x 120 Ø8
80,197
50
300
8423533695215
L -
Length
120
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
50
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
TX30
Shear load non-cracked concrete
263
TNUXA10060
10 x 60 Ø10
75,970
50
300
8423533695222
L -
Length
60
d0 - Ø Broca
10
hnom - Min. anchor depth
70
h1 - Drill hole depth min.
50
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
50
Min. distance to edge “A”
60
SW - Installation key
TX40
Shear load non-cracked concrete
364
TNUXA10080
10 x 80 Ø10
93,397
50
300
8423533695239
L -
Length
80
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
TNUXA10100
10 x 100 Ø10
105,527
50
300
8423533695246
L -
Length
100
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
TNUXA10120
10 x 120 Ø10
121,577
50
300
8423533695253
L -
Length
120
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
50
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
TNUXA10140
10 x 140 Ø10
151,050
50
300
8423533695260
L -
Length
140
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
70
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
TNUXA10160
10 x 160 Ø10
161,223
50
200
8423533695277
L -
Length
160
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
90
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
TNUXA10180
10 x 180 Ø10
220,267
50
150
8423533695284
L -
Length
180
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
110
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
TNUXA10200
10 x 200 Ø10
267,037
50
150
8423533695291
L -
Length
200
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
130
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
TNUXA10230
10 x 230 Ø10
311,377
50
100
8423533695307
L -
Length
230
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
160
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
BZTNXA08080
8 x 80 Ø8
3,071
2
15
8423533422170
L -
Length
80
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
TX30
Shear load non-cracked concrete
263
BZTNXA08100
8 x 100 Ø8
3,071
2
15
8423533422187
L -
Length
100
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
TX30
Shear load non-cracked concrete
263
BZTNXA08120
8 x 120 Ø8
3,071
2
15
8423533422194
L -
Length
120
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
50
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
TX30
Shear load non-cracked concrete
263
BZTNXA10080
10 x 80 Ø10
3,071
2
15
8423533422200
L -
Length
80
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
BZTNXA10100
10 x 100 Ø10
3,071
2
15
8423533422217
L -
Length
100
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
BZTNXA10120
10 x 120 Ø10
3,071
2
15
8423533422224
L -
Length
120
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
50
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
VTNUXA08080
8 x 80 Ø8
5,710
8
8
8423533754073
L -
Length
80
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
TX30
Shear load non-cracked concrete
263
VTNUXA08100
8 x 100 Ø8
7,135
8
8
8423533755261
L -
Length
100
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
TX30
Shear load non-cracked concrete
263
VTNUXA10080
10 x 80 Ø10
9,500
8
8
8423533755278
L -
Length
80
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
VTNUXA10100
10 x 100 Ø10
10,735
8
8
8423533755285
L -
Length
100
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
LSTNXA08080
8 x 80 Ø8
6,549
10
8
8423533771612
L -
Length
80
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
TX30
Shear load non-cracked concrete
263
LSTNXA08100
8 x 100 Ø8
7,798
10
8
8423533771629
L -
Length
100
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
TX30
Shear load non-cracked concrete
263
LSTNXA08120
8 x 120 Ø8
8,586
8
8
8423533771636
L -
Length
120
d0 - Ø Broca
8
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
50
Min. distance from axis "B"
100
Tension load non-cracked concrete
141
Tension load solid brick
26
Mº -
M
8
df - Ø Element to fix
8 - 8,5
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
60
SW - Installation key
TX30
Shear load non-cracked concrete
263
LSTNXA10080
10 x 80 Ø10
9,229
8
8
8423533763822
L -
Length
80
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
10
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364
LSTNXA10100
10 x 100 Ø10
7,040
6
6
8423533763839
L -
Length
100
d0 - Ø Broca
10
hnom - Min. anchor depth
90
h1 - Drill hole depth min.
70
tfix - Max. fixture thickness
30
Min. distance from axis "B"
100
Tension load non-cracked concrete
202
Tension load solid brick
26
Mº -
M
10
df - Ø Element to fix
10 - 11
hmin - Min. substrate thickness
100
hef - Effective depth
70
Min. distance to edge “A”
70
SW - Installation key
TX40
Shear load non-cracked concrete
364