DISTRIBUIDOR OFICIAL INDEX A PERFECT FIXING
(+52) 461.611.0631
CA-QU - Epoxy resin, quartz and a phial of hardener. Opt.8 ETA Assessed.
CA-QU - Epoxy resin, quartz and a phial of hardener. Opt.8 ETA Assessed.
CA-QU - Epoxy resin, quartz and a phial of hardener. Opt.8 ETA Assessed.
CA-QU - Epoxy resin, quartz and a phial of hardener. Opt.8 ETA Assessed.
CA-QU - Epoxy resin, quartz and a phial of hardener. Opt.8 ETA Assessed.

Chemical fixings - CA-QU

CA-QU

Epoxy resin, quartz and a phial of hardener. Opt.8 ETA Assessed. Epoxy resin, quartz and a phial of hardener. Option 8 ETA Assessed.

> CAD data

  • Air conditioning units
  • Balcony railings
  • Road railings
  • Concrete building under construction
  • Industrial shelving
  • Street lights
  • Presses
  • Overhead cranes
  • Overhead cranes
Installation - CA-QU - Epoxy resin, quartz and a phial of hardener. Opt.8 ETA Assessed.
Concrete

Concrete

Solid brick

Solid brick

Stone

Stone

Reinforced concrete

Reinforced concrete

Code Dimension Pcs Box Pcs Masterbox EAN technical info.
CAQU010 10 x 90 Ø12 0,000 10 500 8423533046604
L - Length 90
df - Ø Element to fix 12
hmin - Min. substrate thickness 120
hef - Effective depth 90
Tins - Torque (Nm) 20
Min. distance from axis "B" 180
Tension load non-cracked concrete 1214
d0 - Ø Drill 12
Drill hole depth min. 90
Min. anchor depth 90
tfix - Max. fixture thickness 25
Min. distance to edge “A” 90
SW - Installation key 17
Shear load non-cracked concrete 815
CAQU012 12 x 110 Ø14 0,000 10 200 8423533046703
L - Length 110
df - Ø Element to fix 14
hmin - Min. substrate thickness 140
hef - Effective depth 110
Tins - Torque (Nm) 40
Min. distance from axis "B" 220
Tension load non-cracked concrete 1618
d0 - Ø Drill 14
Drill hole depth min. 110
Min. anchor depth 110
tfix - Max. fixture thickness 32
Min. distance to edge “A” 110
SW - Installation key 19
Shear load non-cracked concrete 1223
CAQU016 16 x 125 Ø18 0,000 10 200 8423533046802
L - Length 125
df - Ø Element to fix 18
hmin - Min. substrate thickness 160
hef - Effective depth 125
Tins - Torque (Nm) 80
Min. distance from axis "B" 250
Tension load non-cracked concrete 2023
d0 - Ø Drill 18
Drill hole depth min. 125
Min. anchor depth 125
tfix - Max. fixture thickness 44
Min. distance to edge “A” 125
SW - Installation key 24
Shear load non-cracked concrete 2272
CAQU020 20 x 170 Ø25 0,000 6 60 8423533046901
L - Length 170
df - Ø Element to fix 22
hmin - Min. substrate thickness 220
hef - Effective depth 170
Tins - Torque (Nm) 120
Min. distance from axis "B" 340
Tension load non-cracked concrete 3034
d0 - Ø Drill 25
Drill hole depth min. 170
Min. anchor depth 170
tfix - Max. fixture thickness 66
Min. distance to edge “A” 170
SW - Installation key 30
Shear load non-cracked concrete 3553
CAQU024 24 x 210 Ø28 0,000 6 60 8423533047007
L - Length 210
df - Ø Element to fix 26
hmin - Min. substrate thickness 260
hef - Effective depth 210
Tins - Torque (Nm) 180
Min. distance from axis "B" 420
Tension load non-cracked concrete 3641
d0 - Ø Drill 28
Drill hole depth min. 210
Min. anchor depth 210
tfix - Max. fixture thickness 62
Min. distance to edge “A” 210
SW - Installation key 36
Shear load non-cracked concrete 5126